Fig. 8a - Minimum Flow
13
COUPLING BOLTS
PUMP
MOTOR FRAME
BOLT
in-lb
N-m
MVI 5,15,20
56C
M6
115
13
182TC
M8
274
31
213TC
M10
549
62
MVI 50,75,100
56C
M6
115
13
182TC
M8
274
31
213TC
M10
549
62
254TC
M10
549
62
MVI 160,225,320,450,600,750
182TC
M10
549
62
213TC
M10
549
62
254TC
M10
549
62
284/6TSC
M10
549
62
324/6TSC
M10
549
62
364/5TSC
M16
885
100
405TSC
M16
885
100
STAYBOLTS
PUMP
BOLT
in-lb
N-m
MVI 5, 15, 20
M12
310
35
MVI 50, 75, 100, 160, 225, 320,450
M16
708
80
MVI 600, 750
M16
1062
120
AIR VENT/DRAIN PLUG
in-lb
N-m
310
35
IMPELLER NUT/LOCK NUT
PUMP
in-lb
N-m
MVI 5, 15, 20
159
18
MVI 50, 75, 100
195
22
MVI 160,225,320,450
885
100
MVI 600, 750
1593
180
STRAP BOLT
PUMP
BOLT
in-lb
N-m
MVI 50,75,100,160, 225, 320,450
M8
133
15
SHAFT END NUT
PUMP
BOLT
in-lb
N-m
MVI 600, 750
M14
398
45
SHAFT END BOLT
PUMP
BOLT
in-lb
N-m
MVI 160,225,320,450
M8
274
31
MOTOR BRACKET & PUMP HEAD BOLT
PUMP
BOLT
in-lb
N-m
MVI 160,225,320,450
M10
549
62
MOTOR BRACKET BOLT
BOLT
in-lb
N-m
M6
89
10
M8
106
12
M12
354
40
M16
708
80
Fig. 8a - Minimum Flow
0
5
10
15
20
25
30
180
190
200
210
220
230
240
250
Qm
in
(%)
t (°F)
Minimum Flow
Tightening Torque Specifications