The electrical connection of the frequency con-
verter must correspond to the diagrams contained
in the following table:

The frequency converter could be dam-
aged if connected incorrectly. 

The electric cable is never to be allowed to
come into contact with either the pipe or the
pump. Furthermore, it must be completely
shielded against moisture.

Property damage is possible!
Because of operational settings, an incor-
rectly disconnected core in the connec-
tion area could damage the frequency
converter.
• Disconnect the core at both of its end

points from electrical connection

• Pull it off

English

WILO SE 05/2008

17

Details concerning the electrical connections - loosen screws and remove upper cover of the frequency converter.

Mains connection

Connect three lines of the cable to the
3 connection terminals of the board.
(Phase + Earth).

Connecting the inputs/outputs

3 operating modes exist: 

(see Chapter 6: Commissioning)

manual mode:

Mode 1

Pressure regulation:

Mode 2

Operation by external control:

Mode 3

NOTE: The configuration at the time of 
delivery is either Mode 1-3 or Mode 2,
depending on the desired type of pump 
control unit. A programming key is used 
to switch from Mode 1-3 to Mode 2 (or vice-
versa); an after-sales service employee must
be called in.

Cores 
Ø 2.5 mm

2

Connection terminal

Main fuse 20 A

Connection terminals

inputs/outputs

(see 
Fig. 3, 
Pos. 20)

(see 
Fig. 3)

+24

V

D

C

m

ax.

30

mA

+

1

0

VD

Cm

a

x

.3

0m

A

Zer

o

V

o

lt

External

ON/OFF

Err

o

r

relays

potential-fr

ee

contact:

250

V–1

A

1 2 3 4 5 6

7 8 9 10 11 12 13 14

L

N

ATTENTION!

PE

+24

V

+24

V

0V

+10

V

ATTENTION!

Summary of Contents for MHIE 1ph

Page 1: ...operating instructions F Notice de montage et de mise en service NL Inbouw en bedieningsvoorschriften E Instrucciones de instalaci n y funcionamiento I Istruzioni di montaggio uso e manutenzione P Man...

Page 2: ...Fig 1 Fig 3 Fig 2 Fig 4 Fig 5 or ou or ou...

Page 3: ...Fig 6 Fig 8 Fig 7 or ou or ou...

Page 4: ...Fig 9 Fig 10...

Page 5: ...operating instructions 15 F Notice de montage et de mise en service 26 NL Inbouw en bedieningsvoorschriften 38 E Instrucciones de instalaci n y funcionamiento 50 I Istruzioni di montaggio uso e manut...

Page 6: ...ticular the failure to observe these instruc tions could lead to the following hazards Failure of important functions of the pump instal lation Hazards to personnel resulting from electrical mechanica...

Page 7: ...ssel Pos 9 or potable water network Pos 10 5 1 Installation Install the pump at a readily accessible location which is protected against external influences excessive rain or sunlight frost and which...

Page 8: ...fications The electrical properties frequency voltage nominal current of the motor frequency convert er are indicated on the name plate of the motor of the pump A check is to be made as to whether the...

Page 9: ...remove upper cover of the frequency converter Mains connection Connect three lines of the cable to the 3 connection terminals of the board Phase Neutral Earth Connecting the inputs outputs 3 operating...

Page 10: ...3 cores 0 V 0 10 V 24 V 1 1 10 V 0 V 24 V 24 V 2 3 4 5 6 7 8 9 10 11 12 13 14 0 V 4 20 mA 24 V 0 V 0 10 V 24 V 2 Connection of the potentiometer Connection terminals Inputs outputs of the frequency co...

Page 11: ...12 13 14 4 Possible connections It is possible to start or stop the pump with the external control potential free contact this function takes precedence over the other functions This external control...

Page 12: ...Diagrams 2 4 3 6 3 2 1 4 2 1 5 3 1 6 3 1 4 3 1 7 3 1 5 4 ATTENTION Operating modes Mode 1 Mode 3 0 20 mA Mode 3 0 10 V Mode 2 PI control sensor 4 20 mA Mode 2 PI control sensor 0 10 V Mode 2 PI contro...

Page 13: ...0 10 Sensor 0 10 V Input voltage V Pressure in of the sensor measurement range 100 0 2 20 Setpoint 0 20 mA Range in which the frequency converter stops Input current level mA Pressure in of the senso...

Page 14: ...ons concerning commissioning see instruction manual for the pressure boosting sys tem During normal operation the status of the LEDs is as follows see Fig 9 Pos 17 18 6 2 Preparatory flushing Because...

Page 15: ...he specification on the pump shield 7 Maintenance The pump s must be de energised and all non authorised restarts must be pre vented before any maintenance work is done Never undertake maintenance wor...

Page 16: ...cannot be rectified then please contact your local professional tradesmen or the Wilo after sales service in your vicinity ATTENTION Display Frequency converter behaviour Fault possible causes Elimina...

Page 17: ...as not been maintained b The suction line has a smaller circ umference than that of the pump c Suction strainer and suction line are partially blocked a Check correct setting of the nominal values set...

Page 18: ...1008 EG Electromagnetic compatibility directive Compatibilit lectromagn tique directive Niederspannungsrichtlinie 2006 95 EG Low voltage directive Direction basse tension Angewendete harmonisierte No...

Page 19: ...EMV Elektromagnetisk kompatibilitet 2004 1008 EG EG Lavspenningsdirektiv 2006 95 EG Anvendte harmoniserte standarder s rlig 1 FIN CE standardinmukaisuusseloste Ilmoitamme t ten ett t m laite vastaa s...

Page 20: ...lint Budapest T 36 23 889500 wilo wilo hu Ireland WILO Engineering Ltd Limerick T 353 61 227566 sales wilo ie Italy WILO Italia s r l 20068 Peschiera Borromeo Milano T 39 25538351 wilo italia wilo it...

Page 21: ...63 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 Erreichbar Mo Fr von 7 17 Uhr Wochenende und feiertags 9 14 Uhr elektronische Bereitschaft mit R ckruf Garantie Kundendien...

Reviews: