Installation and operating instructions • Wilo-Isar BOOST5 • Ed.03/12/2022
Working pressure (bar)
Inflation pressure (bar)
3
1.5
3.5
2
4
2.5
4.5
3
5
3.5
5.5
4
Inflation (Fig. 7)
•
Remove the screw,
•
get a compressor,
•
connect the compressor pipe to the filling valve,
•
inflate the expansion tank to the desired pressure.
7.6
Self-priming operation
CAUTION
Risk of material damage
The pump is set to self-priming operation in the factory. If proper load operation is guaran-
teed or the supply is already pressurised, you can turn off the automatic priming function
by turning the lever (Fig. 5) to the vertical position.
•
Unscrew and remove the drainage screw. Risk of water leakage.
•
Move the red lever into the vertical position to turn off the automatic self-priming oper-
ation.
•
Screw the drainage screw back on and refill the Wilo-Isar BOOST5 with water as de-
scribed in the chapter “Filling and Starting”.
8
Commissioning
8.1
Filling and starting
Filling and starting
WARNING
Qualified personnel only.
CAUTION
Risk of damaging the pump
Never run the Wilo-Isar BOOST5 dry in order to prevent damage to the
mechanical seal.
Load operation (Fig. 4a)
•
Open all the valves to fill the pump with water.
•
Connect the plug to the mains
•
Set the change-over switch to the vertical position
•
Press the button to start the Wilo-Isar BOOST5
Suction operation (Fig. 4b)
•
Unscrew and remove the filler screw and snifter valve screw.
•
Pour around 1.5 litres of water until it comes out of the aeration hole (Fig. 6).
•
Screw the filler screw and snifter screw back on.
•
Open the water valve.
•
Connect the plug to the mains
•
Set the change-over switch to the vertical position
•
Press and hold the buttons at the same time for 5 seconds.
Wilo-Isar BOOST5 enters priming mode.
•
Press the On/Off switch on the control panel to start priming.