Check that the propeller rotates easily, and clean the propeller and mechanical seal
if necessary.
3.
The sealing chamber control (optional) has broken the electric circuit (connection-re-
lated).
⇒
See “Fault: Mechanical seal leakage, pre-chamber/sealing chamber control reports a
fault and switches the mixer off”
Fault: Mixer starts up, motor protection trips after short period
1.
Motor protection switch set incorrectly.
⇒
Have the setting of the trigger checked and corrected by a qualified electrician.
2.
Increased current consumption due to major voltage drop.
⇒
Have the voltage of individual phases checked by a qualified electrician. Contact the
power grid operator.
3.
The connection only has two phases.
⇒
Have the connection checked and corrected by a qualified electrician.
4.
Voltage differences between the phases are too great.
⇒
Have the voltage of individual phases checked by a qualified electrician. Contact the
power grid operator.
5.
Incorrect direction of rotation.
⇒
Have the connection corrected by a qualified electrician.
6.
Increased current consumption due to clogging.
⇒
Clean propeller and mechanical seal.
⇒
Check the pre-treatment.
7.
The density of the fluid is too high.
⇒
Check unit design.
⇒
Contact customer service.
Fault: Mixer runs, but system parameters are not reached
1.
Propeller clogged.
⇒
Clean propeller.
⇒
Check the pre-treatment.
2.
Incorrect direction of rotation.
⇒
Have the connection corrected by a qualified electrician.
3.
Signs of wear on propeller.
⇒
Inspect propeller and replace if necessary.
4.
The connection only has two phases.
⇒
Have the connection checked and corrected by a qualified electrician.
Fault: Mixer does not run smoothly and is noisy
1.
Improper duty point.
⇒
Check fluid density and viscosity.
⇒
Inspect system configuration, and contact customer service.
2.
Propeller clogged.
⇒
Clean propeller and mechanical seal.
⇒
Check the pre-treatment.
3.
The connection only has two phases.
⇒
Have the connection checked and corrected by a qualified electrician.
4.
Incorrect direction of rotation.
⇒
Have the connection corrected by a qualified electrician.
5.
Signs of wear on propeller.
⇒
Inspect propeller and replace if necessary.
6.
Motor bearings have worn.
⇒
Inform customer service; send the mixer back to the factory for reconditioning.