ENGLISH
12
8
Problems, Causes and Solutions
Problem
Cause
Solution
Motor does not run
No supply voltage
Check main fuse, FI switch and supply cable
Fuse defect
Change fuse and, if necessary, eliminate cause of
fuse blow
Overload switch
Temp. of flow medium to high, keep with in the
triggered on
permissible temperature range. If the event of
reoccurrence, contact customer service.
Pump blocked,
contact customer service
Overload switch
triggered on
Booster relay defect
contact customer service
Motor defect
contact customer service
Motor runs, pump
Pressure pipeline blocked
Remove blockage or brucking, carry out test run
does not function
or buckled
Valve in pressure pipeline
open valve
closed
Unit ventilation blocked
Remove ventilation pipe and clean or replace
activated carbon filter
Pump does not
Impeller damaged or
Clean impeller or replace
function properly
dirty
Pipeline blocked
Remove blockage
Lift or loss of pressure too
Use pipeline with a larger diameter
high,
incorrect dimensioning
Pump runs in short
Ventilation blocked
Clean ventilation
intervals
Leak in flap trap
Clean or replace
Motor makes loud
Foreign body in the unit
Dismantle pump and clean or contact customer
noises when rotating
services
If the fault cannot be remedied, please contact your plumbing and heating specialist or your
nearest WILO customer services or representative.
Subject to technical alterations!
Summary of Contents for DrainLift TMP 32-0,5.1
Page 2: ...Fig 1...
Page 3: ...Fig 2 Fig 3...
Page 4: ...Fig 4 Fig 5...
Page 28: ...23...
Page 29: ...24...
Page 30: ......
Page 31: ......