Application/use
en
Installation and operating instructions Wilo-DrainLift SANI-M
9
ƒ
Close the inlet and pressure pipe.
ƒ
Only original parts of the manufacturer may be used. The use of any non-original
parts releases the manufacturer from any liability.
ƒ
Collect any leakage of fluid and operating fluid immediately and dispose of it ac-
cording to the locally applicable guidelines.
ƒ
Clean the device thoroughly.
WARNING! Risk of fire if inappropriate clothing is worn and highly flammable
cleaning agents are used!
Static charging may occur when cleaning plastic parts. There is a risk of fire! Only
wear anti-static clothing and do not use highly flammable cleaning agents.
2.11
Operator responsibilities
ƒ
Provide installation and operating instructions in a language which the personnel can
understand.
ƒ
Make sure that the personnel have received the required training for the specified
work.
ƒ
Provide protective equipment. Ensure that the protective equipment is worn by per-
sonnel.
ƒ
Ensure that safety and information signs mounted on the device are always legible.
ƒ
Train the personnel on how the system operates.
ƒ
Eliminate any risk from electrical current.
ƒ
Demarcate and cordon off the working area.
Observe the following points when handling the device:
ƒ
Use is not permitted for persons under the age of 16.
ƒ
Persons under the age of 18 must be supervised by a technician!
ƒ
Use is not permitted for persons with limited physical, sensory or mental capacities!
3
Application/use
3.1
Intended use
Pumping of sewage containing faeces:
ƒ
In cases where sewage cannot be led to the sewer system via a natural fall.
ƒ
For the backflow resistant drainage in cases where the discharge point is below the
backflow level.
NOTICE! Install grease traps upstream of the lifting unit if pumping greasy sewage!
The version for aggressive fluids (SANI...C) is suitable for pumping:
ƒ
Swimming pool water with a max. chloride content of 1.2 mg/l
ƒ
Aggressive sewage with a pH value of 5 to 12:
–
Rainwater (observe local regulations, e.g. DIN 1986-100)
–
Cleaning agents, disinfectants, dishwashing or laundry detergents
–
Condensate from condensing boiler technology
CAUTION! The fluid in the collection reservoir may not exceed or fall short of the pH
value of 5 to 12!
3.2
Improper use
DANGER
Explosion due to use of explosive fluids!
Use of highly flammable and explosive fluids (gasoline, kerosene, etc.) in their pure
form is prohibited. There is a risk of fatal injury due to explosion! The lifting unit is
not designed for these fluids.
Do
not
use the following fluids:
ƒ
Sewage from drainage objects that are located above the backflow level and can be
drained by natural fall.
ƒ
Debris, ash, rubbish, glass, sand, plaster, cement, lime, mortar, fibrous materials, tex-
tiles, paper towels, wet-wipes (e.g. fleece cloths, moist toilet paper wipes), nappies,
cardboard, coarse paper, synthetic resins, tar, kitchen waste, grease, oil
ƒ
Slaughterhouse waste, disposal of slaughtered animals and animal waste (liquid ma-
nure etc.)
ƒ
Toxic, aggressive and corrosive fluids, such as heavy metals, biocides, pesticides,
acids, bases, salts, swimming-pool water
ƒ
Cleaning agents, disinfectants, dishwashing or laundry detergents in excess
amounts, and such that have a disproportionately high degree of foam formation