background image

Application/use

en

Installation and operating instructions Wilo-DrainLift SANI-L

9

Safety footwear

ƒ

Disconnect device from the mains and secure it against being switched on again
without authorisation.

ƒ

Close the inlet and pressure pipe.

ƒ

Only original parts of the manufacturer may be used. The use of any non-original
parts releases the manufacturer from any liability.

ƒ

Collect any leakage of fluid and operating fluid immediately and dispose of it ac-
cording to the locally applicable guidelines.

ƒ

Clean the device thoroughly.

WARNING! Risk of fire if inappropriate clothing is worn and highly flammable
cleaning agents are used!

Static charging may occur when cleaning plastic parts. There is a risk of fire! Only
wear anti-static clothing and do not use highly flammable cleaning agents.

2.11

Operator responsibilities

ƒ

Provide installation and operating instructions in a language which the personnel can
understand.

ƒ

Make sure that the personnel have received the required training for the specified
work.

ƒ

Provide protective equipment. Ensure that the protective equipment is worn by per-
sonnel.

ƒ

Ensure that safety and information signs mounted on the device are always legible.

ƒ

Train the personnel on how the system operates.

ƒ

Eliminate any risk from electrical current.

ƒ

Demarcate and cordon off the working area.

Observe the following points when handling the device:

ƒ

Use is not permitted for persons under the age of 16.

ƒ

Persons under the age of 18 must be supervised by a technician!

ƒ

Use is not permitted for persons with limited physical, sensory or mental capacities!

3

Application/use

3.1

Intended use

Pumping of sewage containing faeces:

ƒ

In cases where sewage cannot be led to the sewer system via a natural fall.

ƒ

For the backflow resistant drainage in cases where the discharge point is below the
backflow level.

NOTICE! Install grease traps upstream of the lifting unit if pumping greasy sewage!

The version for aggressive fluids (SANI...C) is suitable for pumping:

ƒ

Swimming pool water with a max. chloride content of 1.2 mg/l

ƒ

Aggressive sewage with a pH value of 5 to 12:

Rainwater (observe local regulations, e.g. DIN 1986-100)

Cleaning agents, disinfectants, dishwashing or laundry detergents

Condensate from condensing boiler technology

CAUTION! The fluid in the collection reservoir may not exceed or fall short of the pH
value of 5 to 12!

3.2

Improper use

DANGER
Explosion due to use of explosive fluids!

Use of highly flammable and explosive fluids (gasoline, kerosene, etc.) in their pure
form is prohibited. There is a risk of fatal injury due to explosion! The lifting unit is
not designed for these fluids.

Do 

not

 use the following fluids:

ƒ

Sewage from drainage objects that are located above the backflow level and can be
drained by natural fall.

ƒ

Debris, ash, rubbish, glass, sand, plaster, cement, lime, mortar, fibrous materials, tex-
tiles, paper towels, wet-wipes (e.g. fleece cloths, moist toilet paper wipes), nappies,
cardboard, coarse paper, synthetic resins, tar, kitchen waste, grease, oil

ƒ

Slaughterhouse waste, disposal of slaughtered animals and animal waste (liquid ma-
nure etc.)

Summary of Contents for DrainLift SANI-L Series

Page 1: ...Pioneering for You Wilo DrainLift SANI L 2552854 Ed 01 2020 06 en Installation and operating instructions...

Page 2: ......

Page 3: ...ded use 9 3 2 Improper use 9 4 Product description 10 4 1 Design 10 4 2 Materials 10 4 3 Monitoring devices 10 4 4 Operating principle 11 4 5 Operation with frequency converter 11 4 6 Type key 11 4 7...

Page 4: ...sibilities 25 9 3 Shut down 25 9 4 Removal 25 9 5 Clean and disinfect 27 10 Maintenance and repair 27 11 Spare parts 27 12 Disposal 27 12 1 Protective clothing 27 12 2 Oils and lubricants 27 12 3 Info...

Page 5: ...following cases Inadequate configuration due to inadequate or incorrect instructions by the operator or the client Non compliance with these instructions Improper use Incorrect storage or transport In...

Page 6: ...ation on handling the product Markups Prerequisite 1 Work step list Notice instructions Result Symbols These instructions use the following symbols Danger caused by electric voltage Danger of bacteria...

Page 7: ...wing monitoring devices must be provided on site Circuit breaker The size and switching characteristics of the circuit breakers must conform to the rated current of the connected product Observe local...

Page 8: ...for safety reas ons Toxic or asphyxiating gases may build up in enclosed spaces or buildings Observe protective measures in accordance with work regulations e g carry a gas detector with you Clean th...

Page 9: ...r the age of 18 must be supervised by a technician Use is not permitted for persons with limited physical sensory or mental capacities 3 Application use 3 1 Intended use Pumping of sewage containing f...

Page 10: ...face cooled air or self cooling sheath flow cooling motor with thermal motor monitoring Pre installed switchgear for automatic operation Wilo Control MS L Collective fault signal with potential free c...

Page 11: ...ion on the frequency converter is not permitted 4 6 Type key Example DrainLift SANI L 17T 4C DrainLift Product family SANI Sewage lifting unit L Size 17 Max delivery head T Mains connection M 1 T 3 4...

Page 12: ...or continuous duty The max volume flow applies to continu ous duty S1 4 8 Scope of delivery Lifting unit with switchgear and connection cable with plug Flange connector DN 80 100 Collar DN 100 for pre...

Page 13: ...h lifting gear as a loop to the collection reservoir Secure the lifting gear against slipping Ensure the stability of the lifting equipment during operation Ensure a second person is present to coordi...

Page 14: ...ment Provide protective equipment Ensure that the protective equipment is worn by per sonnel Observe local sewage technology regulations for the operation of sewage systems Structural components and...

Page 15: ...g equipment even surface clean firm base Warehouse and installation location must be easily accessible Attach two transport straps to the lifting unit Secure the transport straps against slipping Only...

Page 16: ...ng Anchor the lifting unit to the floor for this Preparatory tasks have been completed Installation location prepared according to consulting documents Suitable fixation material provided for the exis...

Page 17: ...stalled properly Pressure pipe installed correctly according to consulting documents and perpen dicular to the pressure port Assembly materials provided 1x gate valve 1x collar 4x pipe clamps 1 Instal...

Page 18: ...properly CAUTION Inlet surges or air intake into the collection reservoir can cause the lifting unit to malfunction Lay the inlet pipe with a slope to the lifting unit so that it can drain automatica...

Page 19: ...ipe into the inlet seal Push the inlet pipe 10 20 mm 0 4 0 8 in into the collection reservoir 8 Connect the inlet seal and pipe firmly to the pipe clamp Tightening torque 5 Nm 3 7 ft lb Inlet connecte...

Page 20: ...ation and operating instructions for the diaphragm hand pump 6 5 Electrical connection DANGER Risk of death due to electrocution Improper conduct when carrying out electrical work can lead to death du...

Page 21: ...ume The switching point data always refers to the floor Switching points Setting DIP switch 3 Factory setting se lectable Pump ON 180 mm 7 in Pump OFF 115 mm 4 5 in High water alarm 200 mm 8 in ON 1 2...

Page 22: ...ear to ensure it is correctly operated Settings LED displays LC display Alarm signals 7 4 Test run Carry out a test run before operating the lifting unit in automatic mode A test run checks the proper...

Page 23: ...nnection 9 Venting screw Lifting unit in standby mode 1 Check factory setting of the venting screw 28 mm 1 1 in 2 Unscrew the venting screw if it is screwed in too far 28 mm 1 1 in CAUTION If the vent...

Page 24: ...s drain the collection reservoir in manual mode For all relevant information on manual mode refer to the installation and operating instructions for the switchgear CAUTION Continuous duty is not permi...

Page 25: ...there is a build up of toxic or suffocating gases When working in chambers and closed spaces a second person must be present for safety reasons When using lifting equipment all regulations for working...

Page 26: ...reasons WARNING Risk of burns from hot surfaces Motor housing can become hot during operation It may cause burns Allow the mo tor to cool down at ambient temperature after switching it off Lifting uni...

Page 27: ...or into the drain 5 Let the lifting unit dry out 6 Close inspection opening on the collection reservoir and swing check valve again 10 Maintenance and repair Maintenance and repair work may only be ca...

Page 28: ...sed of along with domestic waste Please note the following points to ensure proper handling recycling and disposal of the used products in question Hand over these products at designated certified col...

Page 29: ......

Page 30: ......

Page 31: ...ilo it Kazakhstan WILO Central Asia 050002 Almaty T 7 727 312 40 10 info wilo kz Korea WILO Pumps Ltd 20 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229...

Page 32: ...Pioneering for You WILO SE Nortkirchenstr 100 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: