en
Installation and operating instructions • Wilo-DrainLift BOX • Ed.06/2022-10
31
•
Disconnect device from the mains and secure it against being
switched on again without authorisation.
•
Clean the device thoroughly.
WARNING! Risk of fire if inappropriate clothing is worn and
highly flammable cleaning agents are used!
Static charging may occur when cleaning plastic parts. There is
a risk of fire! Only wear anti-static clothing and do not use
highly flammable cleaning agents.
•
Close the inlet and pressure pipe.
•
Only original parts of the manufacturer may be used. The use of
any non-original parts releases the manufacturer from any liab-
ility.
•
Collect any leakage of fluid and operating fluid immediately and
dispose of it according to the locally applicable guidelines.
2.9
Operator responsibilities
•
Provide installation and operating instructions in a language
which the personnel can understand.
•
Make sure that the personnel have received the required train-
ing for the specified work.
•
Provide protective equipment. Ensure that the protective
equipment is worn by personnel.
•
Ensure that safety and information signs mounted on the
device are always legible.
•
Train the personnel on how the system operates.
•
Demarcate and cordon off the working area.
3
Application/use
3.1
Intended use
For collection and pumping of the following in domestic areas:
•
Sewage not containing faeces
A grease separator must be installed for pumping greasy sewage!
Sewage pumping according to (DIN) EN 12050
The pumps meet the requirements of EN 12050-2.
Application
•
For the backflow resistant drainage in cases where the discharge point is below the
backflow level.
•
In cases where sewage cannot be led to the sewer system via a natural fall.
•
Installation within a building
Application limits
Improper use and overstraining will cause overflow through the floor drain. The following
application limits must be observed:
•
Max. intake/h:
–
DrainLift BOX-32/8E: 1300 l (343 US.liq.gal)
–
DrainLift BOX-32/11E: 1200 l (317 US.liq.gal)
–
DrainLift BOX-40/11E: 870 l (230 US.liq.gal)
–
DrainLift BOX-32/8D: 2400 l (634 US.liq.gal)
–
DrainLift BOX-32/11D: 2200 l (581 US.liq.gal)
–
DrainLift BOX-40/11D: 1620 l (428 US.liq.gal)
–
DrainLift BOX-32/8DS: 3000 l (793 US.liq.gal)
–
DrainLift BOX-32/11DS: 3100 l (819 US.liq.gal)
–
DrainLift BOX-40/11DS: 1740 l (460 US.liq.gal)
•
Max. pressure in the discharge pipeline: 1.7 bar (25 psi)
Summary of Contents for DrainLift BOX
Page 2: ...DrainLift BOX https qr wilo com 742...
Page 3: ...3 Chinese 4 English 26...
Page 5: ...zh CHS Wilo DrainLift BOX Ed 06 2022 10 5 1 1 1 1 2 WILO SE 2022 1 3 Wilo 1 4 Wilo 2 2 1...
Page 6: ...zh CHS 6 Wilo DrainLift BOX Ed 06 2022 10 1 2 2...
Page 8: ...zh CHS 8 Wilo DrainLift BOX Ed 06 2022 10 2 7 2 8 2 9 3 3 1 DIN EN 12050 EN 12050 2...
Page 51: ......