Wilo Drain MTS 40 Series Installation And Operating Instructions Manual Download Page 5

English

Installation and operating instructions Wilo-Drain MTS 40.../MTS 40E...

5

1 General

1.1 About this document

The language of the original operating instructions is 
German. All other languages of these instructions are 
translations of the original operating instructions.
These installation and operating instructions are an 
integral part of the product. They must be kept readily 
available at the place where the product is installed. 
Strict adherence to these instructions is a precondition 
for the proper use and correct operation of the product.
The installation and operating instructions correspond 
to the relevant version of the product and the underly-
ing safety regulations and standards valid at the time of 
going to print.

1.2 Note on conformity

This product was developed and manufactured in 
accordance with the applicable EU product directives 
with which products in the EU area market are obligated 
to comply. This product therefore complies with the 
relevant, general safety and health requirements of the 
European Union, as well as the published European 
standards and internationally recognised German stan-
dards. Since this product was not intended to be sold 
and used in the European Economic Area, it does not 
have a CE label. It is therefore not permitted to sell it in 
the European Economic Area.

2 Safety

These operating instructions contain basic information 
which must be adhered to during installation, operation 
and maintenance. For this reason, these operating instruc-
tions must, without fail be read by the service technician 
and the responsible specialist/operator before installa-
tion and commissioning.
It is not only the general safety instructions listed under 
the main point “safety” that must be adhered to but 
also the special safety instructions with danger symbols 
included under the following main points.

2.1 Indication of instructions in the operating 

instructions

Symbols:

Signal words:

Information that appears directly on the product, such as

• direction of rotation arrow,
• identifiers for connections,
• name plate,
• and warning sticker,

must be strictly complied with and kept in legible con-
dition.

2.2 Personnel qualifications

The installation, operating and maintenance personnel 
must have the appropriate qualifications for this work. 
Area of responsibility, terms of reference and monitor-
ing of the personnel are to be ensured by the operator. 
If the personnel are not in possession of the necessary 
knowledge, they are to be trained and instructed. This 
can be accomplished if necessary by the manufacturer 
of the product at the request of the operator.

2.3 Danger in the event of non-observance of the safety 

instructions

Non-observance of the safety instructions can result in 
risk of injury to persons and damage to the environment 
and the product/unit. Non-observance of the safety 
instructions results in the loss of any claims to damages.
In detail, non-observance can, for example, result in the 
following risks:

• danger to persons from electrical, mechanical and bac-

teriological influences,

• damage to the environment due to leakage of hazardous 

materials,

• property damage,
• failure of important product/unit functions,
• failure of required maintenance and repair procedures,

2.4 Safety consciousness on the job

The safety instructions included in these installation 
and operating instructions, the existing national regu-
lations for accident prevention together with any inter-

General danger symbol

Danger due to electrical voltage

NOTE:

DANGER!
Acutely dangerous situation.
Non-observance results in death or the most seri-
ous of injuries.

WARNING!
The user can suffer (serious) injuries. 'Warning' 
implies that (serious) injury to persons is probable if 
this information is disregarded.

CAUTION!
There is a risk of damaging the pump/unit. 'Caution' 
implies that damage to the product is likely if this 
information is disregarded.

NOTE:
Useful information on handling the product. It draws 
attention to possible problems.

Summary of Contents for Drain MTS 40 Series

Page 1: ...US Installation and operating instructions Submersible Grinder Pumps Wilo Drain MTS 40 MTS 40E 6044785 Ed 04 2012 04 Wilo USA...

Page 2: ...Fig 1 Simplex and Duplex Package Fiberglass Basin Fig 2 DN 40 1 Dual Guide Suspension Device X H Hmin S1 Hmin S2 S3 4 3 2 1 1 1 5 Hmin S1 Hmin S2 S3...

Page 3: ...1 3 2 Hmin S1 Hmin S2 S3 Start capacitor Operation capacitor U1 V1 Common Black U2 Principal Brown Red Z2 Auxiliary Blue PE Green Yellow Start relay for start capacitor Switch relay 1 2 3 4 5 6 7 8 9...

Page 4: ......

Page 5: ...the operating instructions Symbols Signal words Information that appears directly on the product such as direction of rotation arrow identifiers for connections name plate and warning sticker must be...

Page 6: ...ke void the manufacturer s declarations regarding safety Modifications to the product are only permissible after consultation with the manufacturer Original spare parts and accessories authorized by t...

Page 7: ...max operating hours year MTS 40 200 h MTS 40E 2000 h Motor non immersed S2 8 min max operating time 8 minutes S3 25 2 5 min operation 7 5 min pause Motor Power connection See name plate Voltage toler...

Page 8: ...ng a pipe elbow with DN 40 flange connection The motors are equipped with a thermal winding con tact which automatically switches the motor off upon overheating Monitoring is self switching on single...

Page 9: ...ant reg ulations Backfill the pit Backfill the pit in layers max layer depth 12 in 300 mm all round with non cohesive beds of equal depth sand grit without sharp edged parts grain size 0 1 in 0 32 mm...

Page 10: ...positionautomaticallyandsealsthepressureconnection on the foot elbow through its dead weight Fix the chain on the guide pipe bracket with shackle provide on site 7 1 3 Portable wet well installation...

Page 11: ...is switched parallel to the operating capac itor for approx 1 second After this time has elapsed the starting capacitor is isolated from the operating capacitor 8 Commissioning 8 1 Rotation direction...

Page 12: ...s of the macerator Rinse out the pump housing via the pressure port until no more contamination comes out of the intake chan nels of the macerator Check the cutting gap of the macerator visually check...

Page 13: ...es Pump does not start Interruption to the main supply short circuit Insulation error in the motor winding Check mains voltage Have the cable and motor checked by a con sultant Fuses capacitor defect...

Page 14: ...WILO USA LLC W66 N1253 Forward Way Cedarburg WI 53012 USA Phone 262 204 6600 WILO Canada Inc Bay 7 2915 10th Ave N E Calgary Alberta T2A 5L4 CANADA Phone 866 945 6236 WILO CDN FAX 403 277 9456...

Reviews: