![Wilo COR-1HELIX VE5203/3/VR Installation And Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/wilo/cor-1helix-ve5203-3-vr/cor-1helix-ve5203-3-vr_installation-and-operating-instructions-manual_982862018.webp)
English
Installation and operating instructions Wilo-Economy CO-1, CO/T-1;-Comfort-Vario COR-1
23
5 Product information
5.1
Type key
6 Description of the product and accessories
6.1 General description
The system with its non-self-priming, vertically
(MV... or Helix V...) or horizontally (MH...) mounted
high-pressure multistage centrifugal pump
is
supplied with all pipework installed as a compact
unit ready for connection. The only connections
that have to be made are for the inlet and pressure
pipes and the power mains connection. Systems
from series CO-1 (Fig. 1a and 1b) and COR-1
(Fig. 1d to 1f) are mounted on a steel base frame
with vibration absorbers. Systems from series
CO/T (Fig. 1e) are mounted on a plastic baseplate
together with a plastic break tank.
It may also be necessary to install accessories
ordered and supplied separately.
The systems CO-1 and COR-1 can be connected
to the water supply network either directly (dia-
gram in Fig. 7a) or indirectly (diagram in Fig. 7b).
When supplied with a self-priming pump (special
version), the system may only be connected to the
public water supply network indirectly (system
separation with a non-pressurised break tank).
You will find notes on the pump type used in the
attached installation and operating instructions
for the pump. The systems of type CO/T are pre-
pared for indirect connection to the public water
supply network by the integrated break tank with
level-dependent replenishment and system sepa-
ration.
e.g.: CO-1 Helix V22 08/CE+
CO
CO
mpact pressure boosting system
1
With one pump
Helix V
Pump series reference (see attached pump
documentation)
22
Nominal volume flow Q
[m
3
/h]
08
Number of pump stages
CE+
Control device, in this case
C
ontroller
E
conomy
+
e.g.: CO/T-1 MVI 2 04/ER
CO
CO
mpact pressure boosting system
/T
With integrated break tank for system
separation
1
With one pump
MVI
Pump series reference (see attached pump
documentation)
2
Nominal volume flow Q
[m
3
/h]
04
Number of pump stages
ER
Control device, in this case the
E
conomy
R
egler (controller)
e.g.: COR -1 Helix VE22 03 -GE
CO
CO
mpact pressure boosting system
R
Control by frequency converter
1
With one pump
Helix VE
Pump series reference (see attached pump
documentation)
22
Nominal volume flow Q
[m
3
/h]
03
Number of pump stages
GE
G
rund
E
inheit (basic unit); in other words,
without an additional control device
Controlled by the pump's integrated fre-
quency converter
e.g.: COR-1Helix VE5203/3/VR
CO
CO
mpact pressure boosting system
R
Control by frequency converter
1
With one pump
Helix VE
Pump series reference (see attached pump
documentation)
52
Nominal volume flow Q
[m
3
/h]
03
Number of pump stages
/3
Number of reduced stages
VR
Control device, in this case the
V
ario
R
egler (controller)
e.g.: COR-1MHIE 406-2G-GE
CO
CO
mpact pressure boosting system
R
Control by frequency converter
1
With one pump
MHIE
Pump series reference (see attached pump
documentation)
4
Nominal volume flow Q
[m
3
/h]
03
Number of pump stages
2G
Generation specification
GE
G
rund
E
inheit (basic unit); in other words,
without an additional control device
Controlled by the pump's integrated fre-
quency converter
Summary of Contents for COR-1HELIX VE5203/3/VR
Page 4: ...Fig 2a Fig 2b...
Page 5: ...Fig 3a 20 19 25 24 21 22 20 19 26 27...
Page 6: ...Fig 3b 19 28 20 21 19 20 21 22 23...
Page 7: ...Fig 4 Fig 5...
Page 8: ...Fig 6a...
Page 9: ...Fig 6b Fig 7a Fig 7b...
Page 10: ...Fig 8...
Page 11: ...Fig 9 Fig 10a...
Page 12: ...Fig 10b...
Page 32: ......
Page 33: ......