background image

p. 14

 

 

 

4227862 ed.04

 

 
 

ENGLISH 

1 General 

About this document 

The language of the original operating instructions is French. All other languages of these instructions are 
translations of the original operating instructions. 
These installation and operating instructions are an integral part of the product. They must be kept readily 
available at the place where the product is installed. Strict adherence to these instructions is a precondition for 
the proper use and correct operation of the product. 
These installation and operating instructions correspond to the relevant version of the product and the 
underlying safety standards valid at the time of going to print. 
EC declaration of conformity:  
A copy of the EC declaration of conformity is a component of these operating instructions.  
If a technical modification is made on the designs named there without our agreement or the declarations 
made in the installation and operating instructions on product/personnel safety are not observed, this 
declaration loses its validity. 

2 Safety 

These operating instructions contain basic information which must be adhered to during installation, operation 
and maintenance. For this reason, these operating instructions must, without fail, be read by the service 
technician and the responsible specialist/operator before installation and commissioning. 
It is not only the general safety instructions listed under the main point “safety” that must be adhered to but 
also the special safety instructions with danger symbols included under the following main points. 

2.1 Indication 

of 

instructions 

in the operating instructions  

Symbols: 

 

 

General danger symbol 
 

 

 

Danger due to electrical voltage 
 

 

 

NOTE: ... 
 
 

Signal words: 

 

DANGER!

 

Acutely dangerous situation. 
Non-observance results in death or the most serious of injuries. 

 

WARNING!

 

The user can suffer (serious) injuries. 'Warning' implies that (serious) 
injury to persons is probable if this information is disregarded. 

 

CAUTION!

 

There is a risk of damaging the product/unit. “Caution” implies that 
damage to the product is likely if this information is disregarded. 

 

NOTE 

Useful information on handling the product. It draws attention to 
possible problems. 

Summary of Contents for COHe

Page 1: ...p 1 4227862 ed 04 COHe F Notice de montage et mise en service GB Installation and operating instructions...

Page 2: ...p 2 4227862 ed 04 Fig 1a 9 2 3 4 6 1 8 5 6 7 11...

Page 3: ...ou le non respect des consignes de cette notice de montage et de mise en service relatives la s curit du produit du personnel rend cette d claration caduque 2 S curit La pr sente notice de montage et...

Page 4: ...s m caniques ou bact riologiques Dangers pour l environnement par fuite de mati res dangereuses Dommages mat riels D faillance de fonctions importantes du produit ou de l installation D faillance du p...

Page 5: ...alable du fabricant L utilisation de pi ces d tach es d origine et d accessoires autoris s par le fabricant garantit la s curit L utilisation d autres pi ces d gage la soci t de toute responsabilit 2...

Page 6: ...rtir du r seau eau de ville partir d une b che de stockage En aspiration variante 5 Donn es techniques 5 1 D signation du surpresseur COHe 2 MHI 2 04 CE T 10 COHe Surpresseur avec pompes horizontales...

Page 7: ...une vanne d isolement Rep 6 est mont e c t aspiration et c t refoulement Un clapet anti retour Rep 7 est mont c t refoulement Un sous ensemble avec capteur de pression manom tre purgeur et vanne d arr...

Page 8: ...7 Installation et raccordement hydraulique 7 1 Installation Installer le surpresseur dans un local facilement accessible normalement a r et prot g du gel et de la pluie S assurer que la porte du loca...

Page 9: ...mis la terre de fa on r glementaire conform ment aux prescriptions et conditions locales les connexions pr vues cet effet sont signal es en cons quence voir aussi le sch ma de raccordement lectrique I...

Page 10: ...sion pr r gl e soit tablie ATTENTION Ne pas laisser fonctionner la pompe vanne de refoulement ferm e au del de d une minute 8 3 Mise hors service de l installation Si le surpresseur doit tre mis hors...

Page 11: ...TIONNE PAS Protection thermique d clench e Le voyant d faut pompes sur le coffret doit tre allum V rifier le r glage de la protection thermique et r armer V rifier le sens de rotation le couplage ou l...

Page 12: ...et ou armoire d fectueux Voir la notice du coffret ou de l armoire Fils d connect s Contr ler toutes les connexions au bornier du coffret Transmetteur d fectueux V rifier les contacts changer le trans...

Page 13: ...pecter les prescriptions locales en vigueur Pour des informations sur l limination correcte s adresser la municipalit locale au centre de traitement des d chets le plus proche ou au revendeur aupr s d...

Page 14: ...observed this declaration loses its validity 2 Safety These operating instructions contain basic information which must be adhered to during installation operation and maintenance For this reason thes...

Page 15: ...working operating and safety regulations of the operator are to be complied with 2 5 Safety instructions for the operator This appliance is not intended for use by persons including children with red...

Page 16: ...d from moisture and dust with a transparent plastic cover The equipment must be transported by means of authorised load devices ATTENTION The stability of the load must be ensured since with this part...

Page 17: ...imum working pressure 10 PN10 bars 5 2Technical data Maximum operating pressure 10 bars Maximum water temperature 70 C Maximum ambient temperature 40 C Three phase voltage 50 Hz 230 400V 5 3 Scope of...

Page 18: ...nt and a shut off valve pos 8 is mounted on the discharge manifold As an option a low water protection device not shown shall be retrofitted on the suction manifold when supplied from the public water...

Page 19: ...force The connection of the suction and delivery manifolds can be made either on the right or left hand sides of the installation It is recommended to close the ports that are not used with thread cap...

Page 20: ...s the mechanical seal Dry running protection With public water mains connection pressure switch to be connected to the booster In the tank position the float switch for low water protection so that th...

Page 21: ...water which may leak in very small quantities at the joint In the event of a consequent leakage the mechanical seal must be replaced For long term decommissioning proceed as described in section 8 3...

Page 22: ...re lower than the minimum pressure planned Contact the public water supply company or replace the booster Contact us A pump is obstructed by particles Have the pump dismantled and cleaned Voltage of t...

Page 23: ...d dangers to your personal health NOTE Disposal in domestic waste is forbidden In the European Union this symbol can appear on the product the packaging or the accompanying documentation It means that...

Page 24: ...p 24 4227862 ed 04...

Page 25: ...p 25 4227862 ed 04...

Page 26: ...p 26 4227862 ed 04...

Page 27: ...p 27 4227862 ed 04...

Page 28: ...p 28 4227862 ed 04...

Reviews: