Product description
14
WILO SE 2017-12
PRO C08...
DN 80, PN 10
PRO V10...
DN 100, PN 10
PRO C10...
DN 100, PN 10
Suction connection
PRO V05...
DN 50, PN 10
PRO C05...
PRO V06...
DN 65, PN 10
PRO C06...
PRO V08...
DN 80, PN 10
PRO C08...
PRO V10...
DN 100, PN 10
PRO C10...
* Operating mode S3 50 % is permitted if the necessary motor cooling is guaranteed
before the motor is switched on again! To ensure the required cooling, the motor must
be completely immersed for at least 1 min.!
** S1 operation is dependent on the motor power. Observe and comply with the spe-
cification regarding “non-immersed” operating mode on the rating plate!
4.7
Type key
Example: Wilo-Rexa PRO V06DA-110/EAD1X2-T0015-540-P
PRO
Series
V
Impeller shape
V = vortex impeller
C = single-channel impeller
06
Nominal diameter of pressure connection
D
Hydraulic version:
D = suction side drilled acc. to DIN
N = suction side drilled according to ANSI
A
Hydraulics material version: standard
110
Hydraulics definition
E
Motor version: surface-cooled motor
A
“Motor” material version: standard
D
Seal
D = two mechanical seals
B = cartridge seal
1
IE-efficiency class (derived from IEC 60034‑30)
X
Ex-rated
X = ATEX
F = FM
C = CSA-Ex
2
Number of poles
T
Mains connection version: M = 1~, T = 3~
0015
/10 = Rated power P
2
in kW
5
Frequency mains connection: 5 = 50 Hz, 6 = 60 Hz
40
Code for rated voltage
P
Additional electrical equipment:
O = with bare cable end
P = with plug
4.8
Scope of delivery
▪ Pump
▪ Cable with plug or bare cable end
▪ Single-phase current version with capacitor switchgear
▪ Installation and operating instructions
4.9
Accessories
▪ Suspension unit
▪ Pump support foot