Transportation and storage
en
Installation and operating instructions Wilo-Rexa CUT GE
13
Example: Wilo-Rexa CUT GE03.25/P-T15-2-540X/P
P
Surface-cooled motor with grey cast iron housing
T
Mains connection version: M = 1~, T = 3~
15
/10 = rated power P
2
in kW
2
Number of poles
5
Mains connection frequency: 5 = 50 Hz, 6 = 60 Hz
40
Code for rated voltage
X
Ex rating:
Without = without Ex rating
X = with Ex rating
P
Additional electrical equipment:
Without = with bare cable end
P = with plug
4.8
Scope of delivery
▪ Pump
▪ Cable with plug or bare cable end
▪ Single-phase current version with capacitor switchgear
▪ Installation and operating instructions
4.9
Accessories
▪ Cable lengths in fixed length increments of 10 m (33 ft) up to max. 30 m (99 ft) in
single-phase current version or max. 50 m (164 ft) in three-phase current version
▪ Suspension unit
▪ Pump support foot
▪ External pencil electrode for sealing chamber control
▪ Level control devices
▪ Fixation accessories and chains
▪ Switchgear, relays and plugs
5
Transportation and storage
5.1
Delivery
After receiving the shipment, this must be checked immediately for defects (damage,
completeness). Defects must be noted on the freight documentation! Furthermore, de-
fects must be notified to the transport company or the manufacturer immediately on
the day of receipt of shipment. Subsequently notified defects can no longer be asser-
ted.
5.2
Transport
WARNING
Standing under suspended loads!
Never allow anyone to stand under suspended loads! Danger of (serious) injuries
caused by falling parts. Loads may not be carried over work places where people are
present!
WARNING
Head and foot injuries due to a lack of protective equipment!
Danger of (serious) injuries during work. Wear the following protective equipment:
• Safety shoes
• Safety helmet must be worn if lifting equipment are used!
NOTICE
Only use lifting equipment in a technically sound condition!
Only use lifting equipment in a technically sound condition for lifting, lowering and
transporting the pump. Ensure that the pump does not become jammed during lift-
ing and lowering. Do
not
exceed the max. permissible bearing capacity of the lifting
equipment!