Automatic temperature control (accessory)

When installing a room thermostat, the earth cable (protective conductor yellow-green) 
must be connected.

Fuse exchange

Electrical overload causes
a defective fuse.

Eliminate the cause and replace
the defective fuse by  
unscrewing the safety cap,
inserting a new fuse and 
screwing the safety cap back in.

20 of 26

Summary of Contents for 1850030

Page 1: ...Perfection is our aim Operating Manual Infrared Oil Heater RH 35...

Page 2: ...networks EN 61000 3 3 Voltage fluctuations and flicker on low voltage networks EN 61000 6 4 Electromagnetic compatibility EMC EN 61000 6 2 Electromagnetic compatibility EMC DIN EN ISO 12100 1 2 Safet...

Page 3: ...e manufacturer expressly reserves the right to make unannounced technical changes if they serve to improve the performance or the safety standards of the device 1 of 26 Operating Manual Infrared Oil H...

Page 4: ...4 6 4 Operating Instructions 7 8 5 Specifications 9 6 Assembly Instructions 10 11 7 Starting Procedure 12 13 8 Misfire resetting 14 9 Switching off the heater Restart 15 10 Maintenance RH 35 16 20 11...

Page 5: ...z Power consumption 60 W Rated current 0 4 A Control Flame control with automatic aftercooling Fuse 16 A Combustion system High Pressure Atomization Burner Ignition system High Voltage Transformer Fue...

Page 6: ...GmbH Co KG reserves the right to make changes and improvements of the product and the operating manual without prior notice Safety Informations Safety standards Read this manual carefully before doing...

Page 7: ...reached an unacceptable concentration A good natural ventilation is provided if e g the volume in m at least 30 times the nominal heat load in kW all in corresponds to devices in operation and through...

Page 8: ...are both outdoors and in large rooms e g in halls allowed The heater may be operated only by persons who have been advised in the use of the heater Please refer to the operating manual Instructed pers...

Page 9: ...ion values there are portions of carbon monoxide in the exhaust gases Therefore good ventilation must be ensured If there are signs of poisoning go to the fresh air immediately Electrical safety To av...

Page 10: ...er while it is still hot Never transport the heater with full tank Never use the heater with separate tank Never let children or animals near the heater Never get too close to the heater with your clo...

Page 11: ...9 of 26 RH 35 5 Specifications...

Page 12: ...well as all the packaging material out of the carton Remember to take the axle out of the styrofoam packaging Wheels Pin Spacer Washer Front grill 10 of 26 Carton Contents Screws Screws Nuts 6 Assembl...

Page 13: ...r washer on the axle Secure the wheel with a split pin picture 5 Fig 5 3 Put the heater on the wheel frame and fasten it with two screws 60 mm and nuts on each side picture 6 Fig 6 4 Fasten the front...

Page 14: ...Never store heating fuel in the bright sun or near any heating source Never use old or long stored heating fuel The heater will not operate troublefree with old heating fuel Ventilation Use the heate...

Page 15: ...few seconds If the heater does not start repeat the procedure and take care that the tank is sufficiently filled Check this on the fuel gauge The eclectrical components of the heater are protected by...

Page 16: ...lap setting If the air flap is completely open more than the required air is delivered This reduces the flame length and the oil air mixture is in no good relation More air than required is delivered...

Page 17: ...cooling the fan stops and you can pull the plug Never pull the plug before the cooling process is finished If you pull the plug earlier it can possibly result in heavy overheating and damage of the he...

Page 18: ...r store old heating fuel between the heating periods old heating fuel is bad for the heater Store the heater in a dry well ventilated surrounding Take care that the surrounding is dustfree If possible...

Page 19: ...the tank every 200 operating hours resp when it is necessary Do not use under any circumstance water for cleaning Ingnition electrode Clean it every 600 operating hours resp exchange it After removin...

Page 20: ...ough the nozzle In order to loosen dirt particles put the nozzle into diesel or heating fuel first Fig 19 Photocell The photocell should be cleaned at least once per heating season This depends also o...

Page 21: ...to the correct position refer figure 21 pull out Photocell Fig 21 Filter The oilfilter should be cleaned at least twice per heating season When using dirty fuel an earlier cleaning replacement may be...

Page 22: ...the earth cable protective conductor yellow green must be connected Fuse exchange Electrical overload causes a defective fuse Eliminate the cause and replace the defective fuse by unscrewing the safe...

Page 23: ...Diesel not ignite or parafin cerosene Radiation plate is insufficiently hot Clogged nozzle Replace nozzle Clogged filter Replace filter element Wrong fuel Change fuel Use only heating fuel Diesel or p...

Page 24: ...wer Supply SW1 Switch TH Thermostat Bridge FE Photocell FG Housing Earth HT Oil Preheating optional FM Burner Motor CM Plug IG Ignition Transformer SP Fuel Pump SV Plug RL Operating Lamp AL Misfire La...

Page 25: ...0067 Transport handle 1 9 8400068 Rear frame 1 11 8400070 Frame support 1 12 8400071 Adjustment knob 1 13 8400077 Fuel line 1 14 8400077 Fuel line 1 34 8400092 Bracket 1 35 8400093 Combustion chamber...

Page 26: ...24 of 26 Drawing RH 35...

Page 27: ...let line 1 22 8803250 Pump nozzle grommet 1 23 8805168 Fan motor 1 24 8803477 Step down transformer 1 25 8803373 Controler 1 26 8805169 Burner control cover 1 27 8805170 Ignition transformer 1 28A 880...

Page 28: ...26 of 26 Drawing Burner RH 35...

Reviews: