WILMS 1251385 Operating Manual Download Page 8

2. 

How to stop the heater

 

 

Set main switch to pos. "0".

 

If the heater has been running on position "Heating" (Heizen) it has an automatic 
cooling of the heater until it completely shuts off.

 

 

Important!

 

 

Pull the main plug only after the heater has cooled down and stopped.

 

Before repairing or servicing always pull the main plug.

 

On operation "Ventilation" (Lüften) the unit shuts off immediately.

 

 

3. 

Safety and control devices

 

 

In case there is no flame - for example caused by lack of fuel - the oil burner relay 
shuts off the heater. The control lamp on the side of the burner reset button lights up.

 

 
After the cause of the malfunction has been cleared the reset button can be pushed 
after a waiting time of appr. 60 sec. and the burner can be restarted.

 

 

Combi control

 

 
The combi control is equipped with 3 temperature sensors which are straight in the 
warm air stream.

 

The first sensor controls the starting retardation and the postpurge of the fan.

 

The second sensor controls the operation temperature. If the max. operating 
temperature of 80° C is exceeded, the sensor shuts the burner off while the fan 
continues to run for cooling.

 

The third sensor serves as a safety thermostat against overheating, for example in 
case of malfunction of the fan.

 

After the cause of overheating has been eliminated the reset button of the safety 
thermostat has to be pushed in order to restart the heater.

 

 
 

Room thermostat

 

 
The thermostat has a temperature regulation range of 5° C - 30° C and shuts the 
burner off after the preset temperature has been reached. The fan continues to run 

 

in order to cool the heater down to a temperature of appr. 30° C before it stops. After

 

the room temperature drops several °C the heater automatically starts running again.

 

 

4. 

Transport

 

 
The heater can be transported and is equipped with hooks for crane transportation. 
These hooks are especially marked. Please use only these devices.

 

  

 

 

 

 

 

 

5. 

Cleaning

 

 

The heater should be cleaned minimum once a year. Therefore remove the lid of the 

 

insert (Pos. 10 page 12).

 

 
  

 

 

 

 

- 5 of 17 -

 

Summary of Contents for 1251385

Page 1: ...Operating Manual Oil Fired Heaters BV 385 Perfection is our aim...

Page 2: ...roduct standard for wideband interferences DIN EN ISO 12100 Safety of machinery DIN EN 60335 1 Safety of electrical appliances DIN EN ISO 13857 Safety of machinery safety distances Note The observance...

Page 3: ...devices 5 Combi control 5 Room thermostat 5 4 Transport 5 5 Cleaning 5 6 Trouble shooting 6 7 Important notice for set up 7 8 Length and diameter of fuel lines 8 9 Service position 9 10 Nozzle change...

Page 4: ...plug into the socket switch to position Heizen Heating and set the room thermostat to a low temperature frost protection 230 V only When ordering spare parts please give the type serial number of the...

Page 5: ...n of the room The heater may not be worked on or transported during operation If the heater is used for drying of grain the set up has to be in a right angle in front of the radial fan or alternativel...

Page 6: ...ection IP 44 Capacity kW 110 kcal h 94 600 Air volume m h 8 200 Max fuel consumption appr kg h 9 2 Dimensions L mm 1985 W mm 895 H mm 1385 Weight kg 305 Cone mm 520 Chimney mm 200 Photo cell standard...

Page 7: ...he first starting During this time the oil is preheated so that the sorting out of paraffine is avoided Start the heater only with connected fuel hoses Otherwise the fuel pump will be destroyed During...

Page 8: ...on and the postpurge of the fan The second sensor controls the operation temperature If the max operating temperature of 80 C is exceeded the sensor shuts the burner off while the fan continues to run...

Page 9: ...ntake and shutts off The red lamp return line lights up Air bubbles in the Check oil level in tank suction line Check if the valve at the fuel filter is opened Push reset button On initial start the b...

Page 10: ...the regulations or an installed exhaust pipe as shown in the drawing Never start the heaters connected to just an exhaust pipe which has been lead through the wall Use it only with an additional exhau...

Page 11: ...meter of fuel lines The table refers to Heiz l EL 4 3 cST and inside diameter of the fuel lines In regard of the length of the fuel lines 4 elbows 1 valve and 1 relief valve were considered for the re...

Page 12: ...the housing 10 Change of nozzle Disconnect ignition wire from the electrode Disconnect baffle plate and pull upside Loosen nozzle spanner SW 16 and secure nozzle block with a spanner SW 19 against tur...

Page 13: ...g to the heater set up In order to reach equal combustion values we recommend the use of a draught regulator Measurement A The measurement A refer adjustment table serves as assistance for the burner...

Page 14: ...xhausts CO O 2 9 CO from O 13 2 CO ppm 0 NOx ppm 87 0 CO mg kWh NOx mg kWh Soot Ba 0 1 Temperature Exhaust C 220 1 Ambient C 23 7 Combustion chamber C Various informations Pressure baffle plate hPa 4...

Page 15: ...01 21 6162821 Special Room Thermostat for high humidity with cable and plug 01 22 6162616 Power Cord with Plug 01 23 6162812 Preheater 01 24 6162813 Oil Preheating Spiral 01 25 6162808 Quick Coupling...

Page 16: ...O N Qty 45 6162841 Screwing 02 46 6162842 T Bar 02 47 6162674 Hose Nipple 02 48 6162843 Red Piece 02 49 6162845 Valve 01 50 6162846 Clamp 01 51 6162847 Clamp 02 52 6162848 Bypass Hose 01 53 6162430 C...

Page 17: ...Exploded View BV 385 14 of 17...

Page 18: ...rner 01 09 6163979 Housing without Suction Absorber 01 12 6163980 Pressure Pipe Pump Nozzle Plate 01 14 6163981 Fan Wheel 01 16 6162710 Suntec Pump AS 47 D 01 17 6162751 Fuel Hose 750 mm 02 18 6162644...

Page 19: ...16 of 17...

Page 20: ...17 of 17...