WILMS 1251385 Operating Manual Download Page 5

 
 
 
Read carefully before starting your heater!

 

 
 
 
IMPORTANT NOTICE

 

 
 

This unit is a space heater with indirect heating, heat exchanger and exhaust.

 

The heater may not be set up near explosive or flamable materials and may not

 

be used in explosion or fire endangered rooms. It may also not be used in areas with

 

high dust development. The heater should be positioned at adequate distance to

 

flamable material such as wood etc. It is essential that there is a sufficient ventilation

 

of the room. The heater may not be worked on or transported during operation.

 

 
If the heater is used for drying of grain the set-up has to be in a right angle in front

 

of the radial fan or alternatively with sufficient distance. This has to be done so that

 

the function of the heater is not influenced by the immense suction of the radial fan.

 

 
The heater is 

standard

 equipped with a fuel pre-heating device. This requires also

 

during the heating interruption (during the night, on weekends) tension so it remains

 

effective. Therefore leave the plug into the socket, switch to position "Heizen" (Heating) 
and set the room thermostat to a low temperature (frost protection).

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  

 

 

 

 

- 2 of 17 -

 

Summary of Contents for 1251385

Page 1: ...Operating Manual Oil Fired Heaters BV 385 Perfection is our aim...

Page 2: ...roduct standard for wideband interferences DIN EN ISO 12100 Safety of machinery DIN EN 60335 1 Safety of electrical appliances DIN EN ISO 13857 Safety of machinery safety distances Note The observance...

Page 3: ...devices 5 Combi control 5 Room thermostat 5 4 Transport 5 5 Cleaning 5 6 Trouble shooting 6 7 Important notice for set up 7 8 Length and diameter of fuel lines 8 9 Service position 9 10 Nozzle change...

Page 4: ...plug into the socket switch to position Heizen Heating and set the room thermostat to a low temperature frost protection 230 V only When ordering spare parts please give the type serial number of the...

Page 5: ...n of the room The heater may not be worked on or transported during operation If the heater is used for drying of grain the set up has to be in a right angle in front of the radial fan or alternativel...

Page 6: ...ection IP 44 Capacity kW 110 kcal h 94 600 Air volume m h 8 200 Max fuel consumption appr kg h 9 2 Dimensions L mm 1985 W mm 895 H mm 1385 Weight kg 305 Cone mm 520 Chimney mm 200 Photo cell standard...

Page 7: ...he first starting During this time the oil is preheated so that the sorting out of paraffine is avoided Start the heater only with connected fuel hoses Otherwise the fuel pump will be destroyed During...

Page 8: ...on and the postpurge of the fan The second sensor controls the operation temperature If the max operating temperature of 80 C is exceeded the sensor shuts the burner off while the fan continues to run...

Page 9: ...ntake and shutts off The red lamp return line lights up Air bubbles in the Check oil level in tank suction line Check if the valve at the fuel filter is opened Push reset button On initial start the b...

Page 10: ...the regulations or an installed exhaust pipe as shown in the drawing Never start the heaters connected to just an exhaust pipe which has been lead through the wall Use it only with an additional exhau...

Page 11: ...meter of fuel lines The table refers to Heiz l EL 4 3 cST and inside diameter of the fuel lines In regard of the length of the fuel lines 4 elbows 1 valve and 1 relief valve were considered for the re...

Page 12: ...the housing 10 Change of nozzle Disconnect ignition wire from the electrode Disconnect baffle plate and pull upside Loosen nozzle spanner SW 16 and secure nozzle block with a spanner SW 19 against tur...

Page 13: ...g to the heater set up In order to reach equal combustion values we recommend the use of a draught regulator Measurement A The measurement A refer adjustment table serves as assistance for the burner...

Page 14: ...xhausts CO O 2 9 CO from O 13 2 CO ppm 0 NOx ppm 87 0 CO mg kWh NOx mg kWh Soot Ba 0 1 Temperature Exhaust C 220 1 Ambient C 23 7 Combustion chamber C Various informations Pressure baffle plate hPa 4...

Page 15: ...01 21 6162821 Special Room Thermostat for high humidity with cable and plug 01 22 6162616 Power Cord with Plug 01 23 6162812 Preheater 01 24 6162813 Oil Preheating Spiral 01 25 6162808 Quick Coupling...

Page 16: ...O N Qty 45 6162841 Screwing 02 46 6162842 T Bar 02 47 6162674 Hose Nipple 02 48 6162843 Red Piece 02 49 6162845 Valve 01 50 6162846 Clamp 01 51 6162847 Clamp 02 52 6162848 Bypass Hose 01 53 6162430 C...

Page 17: ...Exploded View BV 385 14 of 17...

Page 18: ...rner 01 09 6163979 Housing without Suction Absorber 01 12 6163980 Pressure Pipe Pump Nozzle Plate 01 14 6163981 Fan Wheel 01 16 6162710 Suntec Pump AS 47 D 01 17 6162751 Fuel Hose 750 mm 02 18 6162644...

Page 19: ...16 of 17...

Page 20: ...17 of 17...

Reviews: