background image

27

Part Number 550-110-832/1014

OWB & OWT

  Series 2 

Oil-Fired Water Boilers – 

Boiler Manual

14 Ratings

AHRI Certified Ratings

Boiler

 Model

(7) 

Burner Input

Heating

Capacity

Seasonal 

Efficiency

Net

Rating

(water)

Boiler

Water

Content

Flue 

Outlet 

Diameter

Minimum 

Chimney

Draft 

Loss

Thru boiler

GPH     MBH  MBH 

(1) (2) (3)

AFUE 

 % 

MBH 

(4) 

 Gallons

Inches 

(5)

Rect

In

Round

In

Height 

Ft

In W.C.

(6)

OWB/OWT3-T-S2

0.70

98

86

86.4

75

10.9

7

8 x 8

6

15

0.010

OWB/OWT3-T-S2

0.95

133

115

85.0

100

10.9

7

8 x 8

6

15

0.020

OWB/OWT4-T-S2

1.00

140

122

86.2

106

13.4

7

8 x 8

6

15

0.010

OWB/OWT4-T-S2

1.20

168

145

85.0

126

13.4

7

8 x 8

6

15

0.010

OWB/OWT5-T-S2

1.20

168

147

86.1

128

15.9

7

8 x 8

7

15

0.010

OWB/OWT5-T-S2

1.45

203

175

85.0

152

15.9

7

8 x 8

7

15

0.015

OWB/OWT6-T-S2

1.40

196

171

86.0

149

18.4

7

8 x 8

7

15

0.010

OWB/OWT6-T-S2

1.75

245

212

85.0

184

18.4

7

8 x 8

7

15

0.015

Notes

1.  MBH refers to thousands of Btu per hour.
2.  Base on 140,000 Btu per gallon.
3.  Based on standard test procedures prescribed by the United States Department of Energy, with combustion conditions of 

13.5 % CO

2

.

4. 

Net ratings are based on net installed radiation of sufficient quantity for the requirements of the building and nothing need be 

added for normal piping and pickup. Ratings are based on a piping and pickup allowance of 1.15. An additional allowance 

should be made for unusual piping and pickup loads.

5.  See page 6 for minimum breeching diameter.
6.  Listed draft losses are for factory-shipped settings.
7.  OWB and OWT boilers are ASME rated for 50 psig working pressure.

®

DOE

Summary of Contents for OWB Series 2

Page 1: ...be installed and serviced only by a qualified heating installer service technician Failure to comply could result in severe personal injury death or substantial property damage When calling or writin...

Page 2: ...air to boiler 4 Should overheating occur do not turn off or disconnect electrical supply to circulator Instead shut off the oil supply at a location external to the appliance if possible 5 Do not use...

Page 3: ...r be installed on carpeting Do not install boiler on carpeting even if foundation is used Fire can result causing severe personal injury death or substantial property damage Foundation 1 Provide a sol...

Page 4: ...east 140 sq in per 1 GPH input 1 sq in per 1000 Btu input of all fuel burning appliances plus requirements for any equipment that can pull air from room including clothes dryer and fireplace When outs...

Page 5: ...ndensation in chimney Place boiler The boiler contains ceramic fiber and fiberglass materials Use care when handling these materials per instructions on page 21 of this manual Failure to comply could...

Page 6: ...ize Minimum chimney height Rectangle Note 2 Round OWB OWT 3 5 8 x 8 6 15 OWB OWT 4 6 8 x 8 6 15 OWB OWT 5 6 8 x 8 7 15 OWB OWT 6 7 8 x 8 7 15 Notes 1 Flue collar on boiler is 7 00 diameter 2 6 3 4 x 6...

Page 7: ...burns should the valve discharge Discharge line must be as short as possible and be the same size as the valve discharge connection throughout its entire length Discharge line must pitch downward from...

Page 8: ...lation and Piping Guides If boiler is connected to heating coils located in air handling units where they can be exposed to refrigerated air use flow control valves or other automatic means to prevent...

Page 9: ...t systems such as converted gravity systems 2 The bypass arrangement shown protects the boiler from damage caused by condensate corrosion due to low return water temperature This method does not provi...

Page 10: ...andard Plumbing Code provided that Boiler water including additives is practically nontoxic having toxicity rating or class of 1 as listed in Clinical Toxicology of Commercial Products Boiler water pr...

Page 11: ...ams shown in this manual give settings for standard equipment Burner wiring Burner harness incorporates a disconnect plug providing a convenient way to disconnect wiring when burner mounting door is o...

Page 12: ...12 Part Number 550 110 832 1014 OWB OWT Series 2 Oil Fired Water Boilers Boiler Manual NOTES This page left intentionally blank...

Page 13: ...13 Part Number 550 110 832 1014 OWB OWT Series 2 Oil Fired Water Boilers Boiler Manual Figure 10 Wiring diagram OWB and OWT boilers 6 Connect wiring continued 4...

Page 14: ...Do not use Teflon tape as an oil pipe sealant It can cause valves to fail creating hazards Use only flare fittings Do not use compression fittings Failure to comply could result in severe personal in...

Page 15: ...When using antifreeze Do not use automotive ethylene glycol undiluted or petroleum based antifreeze Severe personal injury death or substantial property damage can result Use antifreeze especially mad...

Page 16: ...t 7 Test limit control While burner is operating move indicator on limit control below actual boiler water temperature Burner should go off while circulator continues to operate Raise setting on limit...

Page 17: ...earances described above 2 Install barometric control 18 to 20 inches from boiler in breeching 3 Attach manual reset temperature switch near upper surface of enclosed area See Figure 12 4 Wire switch...

Page 18: ...t a m s d i u q i l 2 o t n o i t c u r t s b o y n a e v o m e r d n a r o f k c e h C r e l i o b o t w o l f r i a n o i t a l i t n e v d n a n o i t s u b m o c 3 r o f t n e v r o y e n m i h c...

Page 19: ...ler use a wire flue brush to thoroughly clean between all pins at all angles Be careful not to damage side walls of rear refractory 6 Move to the bottom of the flueways and clean up between the sectio...

Page 20: ...Read manual Section 4 page 7 before proceeding further Safety relief valves should be reinspected AT LEAST ONCE EVERYTHREEYEARS by a licensed plumb ing contractor or authorized inspection agency to en...

Page 21: ...h potentially contaminated clothes separately from other clothing Rinse clothes washer thoroughly NIOSH stated First Aid Eye Irrigate immediately Breathing Fresh air REMOVAL OF FIBERGLASS WOOL OR INST...

Page 22: ...22 Part Number 550 110 832 1014 OWB OWT Series 2 Oil Fired Water Boilers Boiler Manual 12 Replacement parts Figure 16 Boiler section assembly refractories collector hood and burner door assembly...

Page 23: ...let includes rope and hardware for installation OWB OWT 3 386 700 241WT OWB OWT 4 386 700 242WT OWB OWT 5 386 700 243WT OWB OWT 6 386 700 244WT G Tie rod x 10 OWB OWT 3 560 234 491WT Tie rod x 14 OWB...

Page 24: ...2 1 4 x 1 2 self tapping screws 1 Start upper screw in boiler section Do not tighten 2 Slip keyhole opening in back panels behind screw 3 Install lower screw and tighten both screws c Install top pan...

Page 25: ...07 511 405 113WT 5 Circulator gasket universal 2 per boiler 590 317 535WT Circulator hardware kit includes 2 flanges 4 nuts 4 bolts 1 nipple 1 ell 1 NPT OWB OWT 3 OWB OWT 4 1 NPT OWB OWT 5 OWB OWT 6 3...

Page 26: ...Dimensional drawing ALL DIMENSIONS IN INCHES Boiler model number Supply tapping inches NPT Return tapping inches NPT B Combustion chamber depth inches D Jacket depth inches OWB OWT 3 1 1 2 1 1 2 10 1...

Page 27: ...10 OWB OWT5 T S2 1 45 203 175 85 0 152 15 9 7 8 x 8 7 15 0 015 OWB OWT6 T S2 1 40 196 171 86 0 149 18 4 7 8 x 8 7 15 0 010 OWB OWT6 T S2 1 75 245 212 85 0 184 18 4 7 8 x 8 7 15 0 015 Notes 1 MBH refer...

Page 28: ...Part Number 550 110 832 1014 OWB OWT Series 2 Oil Fired Water Boilers Boiler Manual W T 8201 W Calumet Rd Milwaukee WI 53223 28...

Reviews: