PLB-112
Oil Furnaces
–
Furnace Manual
18
11/13
5. DIMENSIONS
AND
RATINGS (continued)
Table 12: Airflow Data, Models with ½ HP PSC Motors
0.2" (W.C.)
0.3" (W.C.)
0.4" (W.C.)
0.5" (W.C.)
0.6" (W.C.)
0.7" (W.C.)
HIGH
1680
1640
1600
1590
1540
1460
MED-HIGH
1210
1190
1180
1160
1130
1110
MED-LOW
1110
1070
1040
1010
970
930
LOW
960
940
920
890
860
830
BLOWER
SPEED
EXTERNAL STATIC PRESSURE WITH AIR FILTER
Table 13: Airflow Data, Models with ¾ HP ECM Motors
SW1- HEAT
DIP switch position
HEAT INPUT
(USGPH)
CFM with SW3-ADJ
DIP switch position A
CFM with SW3-ADJ
DIP switch position B
CFM with SW3-ADJ
DIP switch position C
A
(1=OFF, 2=OFF)
0.68
1160
1275
1045
B
(1=ON, 2=OFF)
0.80
1340
1475
1205
C
(1=OFF, 2=ON)*
0.68
1000
1100
900
D
(1=ON, 2=ON)*
0.80
1160
1275
1045
SW2- COOL
DIP switch position
A/C size
(TON)
CFM with SW3-ADJ
DIP switch position A
CFM with SW3-ADJ
DIP switch position B
CFM with SW3-ADJ
DIP switch position C
A
(1=OFF, 2=OFF)
4.0
1200
1380
1020
B
(1=ON, 2=OFF)
3.5
1050
1210
875
C
(1=OFF, 2=ON)
3.0
900
1035
765
D
(1=ON, 2=ON)
2.5
750
865
640
SW2- COOL
DIP switch position
A/C size
(TON)
CFM with SW3-ADJ
DIP switch position A
CFM with SW3-ADJ
DIP switch position B
CFM with SW3-ADJ
DIP switch position C
A
(1=OFF, 2=OFF)
4.0
1600
1750
1440
B
(1=ON, 2=OFF)
3.5
1400
1540
1260
C
(1=OFF, 2=ON)
3.0
1200
1320
1080
D
(1=ON, 2=ON)
2.5
1000
1100
900
SW4- DELAY
DIP switch position
HEAT INPUT
(USGPH)
PreRun On-Delay
CFM Level - Time
ShortRun On-Delay
CFM Level - Time
Off-Delay
CFM Level - Time
A
(1=OFF, 2=OFF)
0.68
13% - 45 sec.
19% - 60 sec
38% - 3 min.
B
(1=ON, 2=OFF)
0.80
13% - 45 sec.
19% - 30 sec
38% - 3 min.
C
(1=OFF, 2=ON)
All
13% - 45 sec.
100% - 0 sec
100% - 2 min.
D
(1=ON, 2=ON)
All
13% - 90 sec.
100% - 0 sec
100% - 2 min.
No adjustment
required
A/C size
PreRun On-Delay
CFM Level - Time
ShortRun On-Delay
CFM Level - Time
Off-Delay
CFM Level - Time
-
All
NO DELAY
NO DELAY
100% - 90 sec
NOTE:
Disconnect main power to unit prior to changing DIP switch settings.
OIL HEATING MODE
24 VAC input (R) on W only
CONTINUOUS FAN
24 VAC input (R) on G only
In Cooling - Dehumidification mode, with no 24 VAC input to DH, the CFMs are reduced by 15%.
The CFMs shown are reduced by 20% if there is 24 VAC input to Y1 (first stage cooling mode)
PreRun and ShortRun are the periods of time when the the blower starts at very low CFM to minimize the distributon
of cool air in the system and then runs up to normal speed.
Off Delay is the time required to cool down the heat exchanger with low CFMs, to minimize cool draft in the air
distribution system.
COOLING OR HEAT PUMP HEATING MODE
24 VAC input (R) to G, Y/Y2 and O (for cooling)
DELAY PROFILE FOR OIL HEATING MODE
* Alternate adjustment in oil-fired heating mode for higher temperature rise
DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING MODE