Replacements  Parts List 

 

 

REPLACEMENT  PARTS  FOR  MODELS  6008531; 6008532 
 

Ref. 

Number 

Description 

PART  NO.  FOR  MODEL 

6008532 

6008531 

Outer Casing (Less Front Panel) 

7D18 

7D18 

Inner Liner 

7B138 

7B138 

Lower Front Angle 

7A218 

7A218 

Burner Shield 

7B149 

7B149 

Second Chamber 

7C86 

7C86 

Gasket, Chamber Union 

P321919 

P321919 

Combustion Chamber 

7B169 

7B169 

Gasket, Element Face 

P321911 

P321911 

Element Faceplate 

7A220 

7A220 

10 

Gasket, Element Base 

P321912 

P321912 

11 

Switch Box 

7B183 

7B183 

12 

Limit Switch 

P200300 

P200300 

13 

Selector Switch 

P296201 

P296201 

14 

Fan Switch 

P200200 

P200200 

15 

Cover, Switch Box 

11C68 

11C68 

16 

Handle Deflector Baffle 

11C63 

11C63 

17 

Center Front Panel 

7B136 

7B136 

18 

Bottom Front Panel 

7B171 

7B171 

19 

Top Front Panel 

7B147 

7B147 

20 

Fan Shroud 

7B170 

7B170 

21 

Fan Blade 

P200600 

P200600 

22 

Motor 

P321601 

P321601 

23 

Motor Support 

7B46 

7B46 

24 

Vibration Isolator (4 required) 

P022800 

P022800 

25 

Drafthood Faceplate 

7C85 

7C85 

26 

Vent Safety  Switch 

P321958 

P321958 

27 

Drafthood 

7B165 

7B165 

28 

Gasket, Drafthood Front 

P322003 

P322003 

29 

Gasket, Drafthood Rear 

P322004 

P322004 

30 

Heat Deflector 

7C99 

7C99 

31 

Internal Wires  

For reference only 

32 

Transformer 

P024200 

P024200 

33 

Cover, Junction Box 

7B155 

7B155 

34 

Vent Cover 

7B12 

7B12 

35 

N/A 

36 

Header 

7B57 

7B57 

37 

Flue Collar Gasket 

P027100 

P027100 

38 

Diffusing Grille Kit. Two-Way 

6703 

6703 

38 

Diffusing Grille Kit. One-Way 

6704 

6704 

39 

*  Damper 

* Rear Inner Boot 10-

3/4” Long 

* Rear Out

er Boot 10” Long 

* Plaster Ground 

* Rear Grille Two-Way 

6801 

6801 

40 
41 
42 
43 
44 

* Side Inner Boot 10-

3/4” Long 

* Side 

Outer Boot 10” Long 

* Side Plaster Ground 

* Side Grille 

6701 

6701 

45 
46 
47 
44 

* Side Inner Boot 1

” Long 

* Side Grille 

6702 

6702 

47 
48 

Hinge Wire Extension (2 Required) 

7A225 

7A225 

49 

Support, Second Chamber 

7A219 

7A219 

50 

Manifold 

P323658 

P323658 

51 

Manifold Adaptor 

P321888 

P321888 

Summary of Contents for 6008531

Page 1: ...a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS O...

Page 2: ...ov er claims which do not inv olv e def ective workmanship or materials DUTIES OF THE CONSUMER 1 The heating equipment must be installed by a qualif ied installer and operated in accordance with the i...

Page 3: ...tallation 21 23 Start Up Procedure 24 Operating Your Furnace 25 26 How To Care For Your Furnace 27 28 Furnace Technical Information 28 TROUBLESHOOTING CHART 29 30 Wiring Diagrams 30 Repair Parts 31 32...

Page 4: ...or death 8 Install the furnace vent directly to the outdoors so that harmful combustible flue gases will not collect inside the building Follow the venting instructions for your type of installation e...

Page 5: ...p forces air down along the front back and sides of the heat exchanger where it is discharged into the room The furnace cabinet is also constructed ofheavy gauge steel and has a neutral beige color en...

Page 6: ...enclose the vent pipe from the top of the surface to the ceiling SIDE OUTLET GRILLE KIT 6702 as shown on Page 22 Fig 31 Allows you to direct heated air from the side of furnace into the same room NOT...

Page 7: ...11 Recessed Mounting Place the furnace near the center of the space to be heated for good air circulation Do not put it behind a door or draperies Do not instatl the furnace in a closet alcove of smal...

Page 8: ...e heated area The high cost of energy for home heating has brought about new materials and methods used to constructor remodel most current homes The improved construction and additional insulation ha...

Page 9: ...special provisions are made such as ventilation grilles installed between connecting rooms Fig 6 page 10 shows the minimum area in square feet based on 8 foot ceiling heights required for different B...

Page 10: ...00 square inches or 1 square inch per 1000 Btuh combined input of appliances in one room if combined input exceeds 100 000 Btuh WARNING Danger of property damage bodily injury or loss of life The adjo...

Page 11: ...about 14 inches from the one found Drive finishing nails on the inside of this stud Draw wall cutout to required size as shown on Page 13 Fig 13 If wall studs are not on 16 inch centers see CLOSE OFF...

Page 12: ...t to damage any furnace components while making any alternate hole Locate and drill one 1 1 1 2 inch hole at selected locations as shown on Page 12 Fig 11 and Page 13 Fig 13 or Page 14 Fig 14 Gas line...

Page 13: ...nd electrical connections CUT CEILING OPENING Mark off and cut 3 1 2 x 12 inch rectangular hole in ceiling centered between wall studs The back edge of the opening should be about1 8 inch from the wal...

Page 14: ...f Refer to typical venting system as shown on Page 16 Fig 18 Type B W gas vent shall extend from the header plate of the vented wall furnace to a point above the highest ceiling plate within a stud sp...

Page 15: ...ailed between ends must be bent at 90 degrees INSTALL SURFACE VENT SURFACE MOUNT NOTE For surface mounting itwill be helpful to complete the gas piping supply to the furnace before installing the vent...

Page 16: ...y attic insulation to allow the free circulation of air around oval vent piping Mounting Your Furnace To obtain adequate clearance for fastening furnace or to install gas supplyfittings it may be nece...

Page 17: ...INATE AIR LEAKS FASTEN FURNACE BOTTOM SURFACE AND RECESSED MOUNT NOTE Fasteners are not furnished because of different requirements of various types of wall construction Fasten furnace to floor throug...

Page 18: ...olumn Gas pressure and input to the burners must not exceed the rated inputand pressure shown on the rating plate On Natural Gas the manifold pressure should be 4 inches water column The manifold pres...

Page 19: ...s may damage the gas valve and cause over firing which may result in heat exchanger failure Liquid petroleum L P Gas is heavier than air and it will settle in any low area including open depressions a...

Page 20: ...r obstructions in the partition Then drill a 1 2 inch hole through wall at the selected location for thermostat 5 From the attic feed the thermostatcable or a stiff wire through wall until even with t...

Page 21: ...used the furnace casing must be a minimum of 12 inches from an adjacent side wall as shown on Page 8 Fig 3D CUT CASING OPENING S Before setting the furnace into position cut a 5x7 inch rectangular ope...

Page 22: ...ed REAR OUTLET ONLY Place Inner Boot in position and fasten with screws along the top and bottom edges only Place Damper Assemblyinside Inner Boot and fasten with one 1 screw on each side Thread chain...

Page 23: ...IT MODEL 6704 Follow instructions for 2 WAY FRONT DIFFUSING GRILLE 6703 except furnace clearance to an adjacent wall must be 3 4 inch minimum See Page 8 Fig 3A TRIM STRIP KIT MODEL 4701 When desired o...

Page 24: ...ctory sized orifices If L P gas having a different heating value is supplied orifices must be changed by a qualified service technician before the furnace is operated CHECK THE MANIFOLD GAS PRESSURE A...

Page 25: ...limit switch shuts down the main burner to prevent overheating the furnace cabinet 4 A vent safety shutoff device shuts down the main burner to protect againstimproper venting of combustion products T...

Page 26: ...f all electric power to the appliance 4 Remove control access panel 5 Turn gas control knob clockwise to OFF 6 Wait five 5 minutes to clear out any gas then smell for gas including near the floor If y...

Page 27: ...cabinet door and front panel Clean any lint or dirt from fan blades fan motor and exposed air passages Use a brush Put 5 drops of SAE 20 oil in each of the two cups or oil tubes on the fan motor See F...

Page 28: ...ESULT IN A YELLOW FLAME WHICH CAN PRODUCE CARBON MONOXIDE AND SOOT THIS CONDITION IF ALLOWED TO DEVELOP CAN LEAD TO BODILY INJURY INCLUDING DEATH IT IS IMPERATIVE THAT THE BURNER S BE KEPT GLEAN TO RE...

Page 29: ...orifice plugged Clean or replace orifice if okay and still no gas flow to main burners proceed to Step F F Gas valve defective Replace defective gas valve 3 Burner comes ON but goes OFF before blow e...

Page 30: ...loose on motor shaft Blow er may be rubbing on fan shroud Motor may need oiling Correct as needed B Expansion noise ticking Check installation casing may be tw isted or not level at time of installati...

Page 31: ...Replacement Parts Accessories 31 6008531 6008532 6008531 6008532 34 35...

Page 32: ...Replacements Parts 32...

Page 33: ...22 Motor P321601 P321601 23 Motor Support 7B46 7B46 24 Vibration Isolator 4 required P022800 P022800 25 Drafthood Faceplate 7C85 7C85 26 Vent Safety Switch P321958 P321958 27 Drafthood 7B165 7B165 28...

Page 34: ...ouple P321838 P321838 58 Flame Sensor 59 Pilot P179700 P179800 60 Burner Spacer 2 Required P018100 P018100 61 Burner Cast Iron P025600 P025600 62 Wire Assembly Vent Safety P322048 P322048A P322048 P32...

Page 35: ...onnect the cord a t the receptacle connector located at the base of the furnace and remove the cord completely from the furnace Following the wiring diagram below make all the necessary wiring connect...

Page 36: ...exactly a fire or explosion may result causing property damage personal injury or loss of life Williams Furnace Company 250 West Laurel Street Colton CA 92324 909 825 0993 FAX 909 824 8009 www wfc fc...