IR T2 Infrared Transmitter Programmer’s Guide

Available Commands

When in Command Line Mode, the following commands can be used. Press Enter to execute any command.

COMMAND

FUNCTION

audio_minmax_reset

Reset CHA & CHB audio capture data

audio_minmax_cha

min and max of CHA audio since reset

audio_minmax_chb

min and max of CHB audio since reset

sleep_now

Put the IR T2 to sleep immediately, if there is no audio

wake_now

Wake up the IR T2 immediately, even without audio

mute_audio_input=on

Mute the audio (on reboot, the audio will not  be muted)

mute_audio_input=off

Unmute the audio

ir_low_power_mode=0

Put the IR T2 in full power mode for stronger infrared coverage

ir_low_power_mode=1

Put the IR T2 in 1/2 power mode for less infrared coverage

rf_band_select=0

Change the broadcast channel(s) to 2.3/2.8 MHz IR

rf_band_select=1

Change the broadcast channel(s) to 3.3/3.8 MHz IR

restore_defaults

Reset all settings to the default

reboot_unit

Restart the IR T2

visible_leds=enable

Turn on the LED status indicator lights on the back of the unit

visible_leds=disable

Turn off all of the LED status indicator lights on the back of the unit

visible_leds=blink_5sec

Turn off and on all of the LED lights for 5 seconds

unique_id

Display the unique identifier for this IR T2 unit

When 

help

 is typed into the command prompt (CMD: ) the information below will be displayed:

Summary of Contents for IR T2

Page 1: ...IR T2 PROGRAMMER S GUIDE MAN 227B ...

Page 2: ...ontents IR T2 Programmer s Guide 3 IR T2 Blink Codes 3 Accessing the Terminal Interface 3 Monitoring Mode 5 Monitoring from a 3rd party system Crestron QSC AMX etc 5 Command Line Mode 5 Hot Keys 5 Available Commands 6 Command Feedback 7 Restarting the Device 7 ...

Page 3: ...nal Interface The IR T2 has a Control port that is RS 232 compatible It can be connected directly to a computer or other 3rd party system Crestron Kramer Extron QSC etc for control and monitoring To use the terminal as an interface 1 Connect a TTL 232R 3V3 WE cable made by FTDI or an equivalent cable to the Control Phoenix style connector on the back of the IR T2 Only three wires are used for the ...

Page 4: ...e the serial connection setting names may differ for your terminal program Serial line to connect to the Com Port gathered from the device manager in Step 3 Ի Ի In this example it is COM6 Speed baud 115200 Data bits 8 Stop bits 1 Parity None Flow Control None ...

Page 5: ...her information that has not changed Use the ASCII character for left bracket 0x005B as the opening delimiter Set up the 3rd party control monitoring system to trigger capture on an equal sign 0x003D Set up the 3rd party control monitoring system to end the capture on a carriage return 0x000D line feed event 0x000A Repeat the above two capturing steps until the closing delimiter is encountered Ի Ի...

Page 6: ... ir_low_power_mode 0 Put the IR T2 in full power mode for stronger infrared coverage ir_low_power_mode 1 Put the IR T2 in 1 2 power mode for less infrared coverage rf_band_select 0 Change the broadcast channel s to 2 3 2 8 MHz IR rf_band_select 1 Change the broadcast channel s to 3 3 3 8 MHz IR restore_defaults Reset all settings to the default reboot_unit Restart the IR T2 visible_leds enable Tur...

Page 7: ... When the device resets whether due to a command or due to an error additional information will appear in the terminal Most of this information is about the firmware version on the IR T2 which could be used to check compatibility with the monitoring on a third party system if needed The age of the meter and the time spent emitting infrared is tracked Both of these fields are tracked in days minute...

Page 8: ...info williamsav com www williamsav com 800 843 3544 INTL 1 952 943 2252 2019 Williams AV LLC MAN 227B ...

Reviews: