Making Menu Selections
Keyboard:
Use arrow to move to your selection and
press the Enter key.
Touch Screen (or Whiteboard):
Tap the screen over the
option you want to select.
Network Setup
1. Activate the menu system.
The Main Menu appears.
2. Select the
Network
option. The Network Menu
appears.
3. Select
Network Setup.
The Network Setup menu
appears. This dialog prepares the CR-400 for
communicating on your network.
4. Select
DHCP
or
STATIC
. Consult with your IT
administrator if you need help with these entries.
• If
DHCP
is selected, IP Address, Netmask, Gateway
and Nameserver are assigned automatically.
• If
STATIC
is selected, you must make entries for IP
Address, Netmask, Gateway and Nameserver.
5. Enter the hostname, if desired. The hostname must
be one word with no spaces.
6. Select
Apply Settings
to finish the network
configuration.
7. Exit the menu system.
Selecting Video Sources
If the correct video source was not automatically
selected:
1. Activate the main menu.
2. Select
Display
.
The Display menu appears.
3. Select
Video Source
. The video source menu
appears.
4. Select from HDMI, USB, Streaming, or chalkboard.
5. If streaming, enter any additional stream information.
6. Select the video source you wish to use, and exit the
menu system.
C
alibrating Touch Screen Controllers
Calibration ensures an intuitive and precise feel to
drawing and marking over the particular moni tor you are
using.
Calibrations are automatically saved for each video port.
If you move a touch screen to a different port, run the
calibration again. If you have a touch screen display with
multiple video inputs, you should calibrate the touch
screen for each input.
All calibrations are stored in battery backed-up memory.
The most recent cali bration will be recalled any time
power is cycled off and on.
From the Menu System
1. Activate the menu system.
The Main Menu appears
.
2. Select
Devices
.
The Devices menu appears
3. Select
Calibration.
The Calibration Menu appears.
4. In the Calibration Menu, select the
controller
you
want to calibrate. The calibration screen for the
selected controller appears.
5. Follow the calibration instructions displayed
on-screen. As you touch the target, it will disappear
and the next target will appear. Repeat until all 12
targets have been calibrated. After you perform
final calibration procedures, the Calibration dialog
automatically disappears, and you return to the menu
system.
6. Exit the menu system. Repeat this process for each
video input on your touch screen display.
For Additional Information
This manual is a quick start guide for getting your
Pointmaker device up-and-running. It covers basic cable
connection and setup. Most features and customization
options are not documented in this manual.
For additional information, feature instructions,
commands, warranty information and more, please
download the full user manual from the Pointmaker
CR-400 product page on Pointmaker’s website.
[email protected] / www.williamssound.com
800-843-3544 / INTL: +1-952-943-2252
© 2018, Williams AV, LLC MAN 230A