Figure 1-2 INFLEXION 4.5 Model Number 722069001 Dimensions
1.5 MAST LOAD
It is important that the mast be securely mounted to a sturdy platform, which will not overturn during operational loading
of the mast. Following is the loading information for the mast, which can be expected during operation:
75 lb at saddle of mast (Inflexion 1.5 and 2.3) or 120 lb saddle of mast (Inflexion 3.0, 4.5, 6.0, and 7.5)
200 lb at the front of the base cover
575 lb at rear of base cover (mast pivot)
1.6 POWER REQUIREMENTS
DC power for the INFLEXION is supplied by the vehicle and customer-wired to the mast base board. The INFLEXION
operates at 12 VDC, but will accept 24 VDC with the optional 24/12 converter. The DC cables should be 12 gauge (for
12V) and 16 gauge (for 24V). Long runs of cable can introduce power loss. There is a 35-40 amp inrush to the motor
(depending on the length and gauge of the wires) that drops to 6-7 amps in 300mS. For long runs, it may be necessary
to increase the wire gauge of the cables. If required, the vehicle-integrator is responsible for installing an ON/OFF switch
to disconnect power from the unit. This switch should be in line with the positive power cable (from battery source). If
using a separate power supply, it should have a 10 amp minimum.