59
NOTE!
•
Remove the active carbon filter before seasonal storage and install new
filters at the beginning of the new season. The old filters can be
disposed in the ‘Nonbiological garbage container’.
•
Replacement filter packages are available directly from Amcor.
•
To run the unit without active carbon filter does not do any harm to
the air
conditioner. In this case odours are not removed from the circulated
air.
The screen filter must always be used.
EMPTYING THE INTERNAL WATER CONTAINER
Under high humidity conditions it may be necessary to empty the internal water
container. When the internal water container is full the backlight on the LCD-
display flashes. The unit will switch off automatically. To empty the water
container do the following:
•
Switch off the unit and remove the plug from the wall socket. Do not
move the unit. Doing this can result in water leakage, damaging your floor
or carpet.
.
Place the water container on the floor underneath the permanent
drainage point.
Remove the water stopper and rubber plug from the drain and let the water
run out. The water container has to be emptied several times before all
water will be drained (ca. 1.5 litres).
.
Replace the rubber plug and water stopper, put the plug into the wall
socket, and switch the unit on. The warning signal should be off.