9
English
P.
8
English
P.
Storage
Drain out water in tank and body, clean the dirt, wipe out water and airing
the machine
Ensure that no water in the machine and put it to the carton
Storage the package in dry place.
Problem solution
Problem
Possible reasons
Solutions
No steam
Check plug
Plug into socket
Check power knob/switch
Turn on power switch
No water in tank
Add water
Scaling on the steam element
Rinse with mixture of 0,5l water and
2 tablespoons vinegar.
Peculiar
smell
steam
New machine
Take off tank cover, place the water
tank in cool and dry place for 12 hours
Too dirty water, or the water has
been there too long
Clean water tank and use clean water
Noise
Tank in incorrect position
Put the tank in correct position
Little water in tank
Add water
Uneven level for machine
Place it on even surface
Packing list
Parts
Amount
Humidifier
1 pc
Manual
1 pc
Clean brush
1 pc
Technical Parameter
Model
SH8201
Power voltage
220~240V AC
Input power
30W (cool steam)
Input power
130W (hot steam)
Max steam volume
≥300ml/h( cool steam)
Max steam volume
≥400ml/h (hot steam)
Tank capacity
6 L
Measurements
338×244×380mm
Placement
Place the product on firm, flat surface. The humidifier should be placed on
flat horizontal surface and keep it steady.
Do not place the product near or close to any heat sources. The humidifier
should be far away from any heat sources, such as stoves or fire places. Do
not expose the product to direct sunlight.
Do not place the product near or close to furniture or electric appliances.
The mist outlet from the humidifier should not be directed towards furniture
and the electronic appliances, to avoid damage. Particles in water, such
as calcium, can be part of the vapour and be deposited on objects in the
vicinity.
It is recommended that the unit be placed on a table or other surface at
least 70 cm above the floor level, to ensure that the vapour will be optimally
distributed throughout the room.
Cleanness & Maintenance
Before cleaning. Turn the unit “Off” and disconnect the plug from the
socket.
Water filter
Water filter should be replaced once a year. Can be bought separate.
Transducer
If you have hard water in your area the transducer may build up scale formation.
Rinse with water and vinegar (0,5l water and 2 tablespoon vinegar) and let it
soak from 2 – 5 minutes. Then rinse with water.
Water bay on the unit
Take out the water in bay. Clean the scale by brush, then wiped by
damp cloth.
Rinse it with water only.
Water tank inside
With frequently use clean water tank inside with water once per week.
Use soft cloth to take away potential scaling.
Remove dirt inside the tank wall with a soft cloth.
Use only water to clean inside the tank.
Body and water tank outside
Wipe it with soft cloth.