![Wilfa Dry M Operating Instructions Manual Download Page 82](http://html.mh-extra.com/html/wilfa/dry-m/dry-m_operating-instructions-manual_981334082.webp)
18
English
English
Bucket full indicator is
lit up.
•
Bucket is not properly placed.
•
Water is full in the bucket.
•
Bucket has been removed.
•
Empty the bucket and replace it.
• Dehumidifier does not dry air as intended.
Problem
Possible Causes
Solution
Bad dehumidifying
performance
•
Check whether there is any
obstacle around the unit.
•
Make sure there is no curtain
shutter or furniture that blocks the
dehumidifier.
•
Air filter is dusty and blocked.
•
Clean the filter.
•
Doors and windows are left
open.
•
Make sure all doors and windows
and other opening to the outside
have been closed.
•
Room temperature is too low.
•
Warm temperature is good for
dehumidification. Low temperature
will reduce unit’s working effect. This
unit should be working in a place
where temperature is above 5° C.