4.
Carefully place the adapter plate onto the oven top, aligning the screw holes. Bolt
down the plate using the concretes screws. Wipe away any excess cement around
the edge of the plate using a cloth.
5.
Allow the cement to dry per manufacturer’s instructions.
6.
Upon drying, attach a section of pipe. The chimney used will have a 6” inside
diameter. The chimney length affects airflow in the oven. We recommend a minimum
of 48” of pipe to ensure proper air flow.
7.
Attach your chimney cap with the spark arrestor.
Refer to NFPA 96
NOTE
: The exhaust hood must be no less than 24” from the top of the oven dome.
Creosote Formation and Removal
.
WARNING: COMMERICIAL-WHEN INSTALLING EXHAUST HOOD ABOVE THE OVEN, REFER
TO THE EXHAUST HOOF MANUFACTURER’S RECOMENDATIONS FOR INSPECTION,
MAINTENANCE AND CLEANING.
VENTING, VIA DIRECT VENTING OR EXHAUST HOOD, MUST BE ACCOMPLISHED IN
ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION
OF COMMERCIAL
IT IS NEVER APPROPRIATE TO USE “CLASS A” OR “B VENT” IN ANY PART OF THE EXHAUST
SYSTEM. EXHAUST SYSTEMS SERVING SOLID-FUEL EQUIPMENT MAY NOT BE COMBINED
WITH EXHAUST SYSTEMS SERVING OTHER (NON-
SOLID FUEL) COOKING EQUIPMENT**
TYPE-I EXHAUST HOOD-INSTALLED PER NFPA 96, IS STANDARD FOR VENTILATION
CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS.