W01-02PRI Installation Admin Guide - English
W01-02PRI Installation Admin Guide - English
Page 8 of 11
Cancel an action that was started
Revert to known factory settings if the device refuses to work properly for any reason or the connection to
the network is lost
Reconfigure the device
The Reset/Default switch will generate different actions depending on the amount of time the button is held.
Pressing
Time
Action
Comment
LED Pattern
2 to 6
seconds
Restarts W01/02PRI
No changes are made to device's
settings
Power1
blinking, all
other LEDs OFF
7 to 11
seconds
Initiates a Partial Reset of the device
Restarts the device in a known and
static state while keeping most of
the configuration unchanged
All LEDs
blinking, 1cycle
per second,
50% duty
12 to 16
seconds
Initiates a Factory Reset of the device
Reverts the device back to its
default factory settings
All LEDs steady
ON
17
seconds
and
more
No action is taken. This is useful if you
accidentally pushed the button and do
not need and action to be applied
The action is ignored
N/A
Partial Reset
The partial reset provides a way to contact W01/02PRI in a known and static state while keeping most of the
configuration unchanged.
A partial reset can be performed at the initial start-up of the device or on a device already in use where the
configuration was modified in such a way that the user can longer access the system by the web page or
otherwise. In both cases, the user will access the Rescue Interface with the Rescue Network Interface using
either a static IPv4 address (192.168.0.1 ) or an IPv6 Link Local address connection. These connections give
access to the Rescue Management Interface where the configuration of a new unit can be completed and where
an existing configuration can be modified.
By default the Rescue Network Interface is disabled. When a partial reset is performed, the Rescue network
Interface becomes enabled. Once the configuration has been modified to solve the problem that required the
partial reset, it is important to access the Management interface using the Network Interface Configuration
defined for your set-up, and to disable the Rescue Network Interface to make sure that you are no longer working
in the Rescue Network Interface.
Performing a partial reset on a new device will not modify the configuration, as it has not yet been modified to
your needs. However, a partial reset performed on a device already in use will:
Cancel the changes that were being modified but not yet applied to the configuration
Disable any Network Interface in conflict with the Network Rescue Interface
Configure and enable the Rescue Network Interface to:
use the Eth1 link, or the same link as the one used by the Uplink Network Interface