7 - Speaker output interface: connect external speakers or microphones

8 - Ground screw: connect external parts with metal housing to this interface to prevent static electricity and other 

interference caused the equipment to work abnormally

Rear panel

1 - Speaker interface: according to the device input voltage adaptive output maximum power; 4 speaker, POE / 

8W, 12V / 10W, 18V / 20W, 24V / 30W. The greater the horn impedance, the smaller the output power. 

Suggested wire diameter: 18AWG or larger diameter

2 - Headset interface: connect external headsets or active speakers

3 - LED interface: 5V output, connect an external LED, indicating the network, call and registration statuses

4 - Function key interface: connect switch components to this interface

5 - Microphone interface: it is recommended to use an electret condenser microphone (sensitivity: -38dB, bias 

voltage: 2.2V) and connect it with a shielded cable to the grounding screw to improve anti-interference

6 - Switch input interface: connect emergency switches, door sensors and other switch components to this 

interface

7 - Switch output interface: corresponds to the short-circuit input interface, allows to control electric locks, alarm 

lights and other equipment

8 - Power input interface: 12

 input, according to the input voltage, determine the maximum W-PA output 

~24V 2A

power amplifier

Installation of W-PA SIP Public Announcer

Connecting W-PA 

Use five or super five network cable to connect your W-PA to the network

Connect the cable to WAN (PoE) port 

Provisioning of W-PA 

Wildix supports different provisioning modes:

Note: a power adapter is optional and used for power supply of any external connected equipment.

Summary of Contents for W-PA SIP Public Announcer

Page 1: ...ouncer is used to broadcast emergency messages and communication in large environments such as shopping malls supermarkets airports hospitals The device has 10 Watt audio output and it still allows you to connect external loudspeakers and microphones It can also act as a relay for activating door release switches or door locks via 1 embedded short in detect port and 1 short out control port See W ...

Page 2: ...per repair may lead to injury accident or cause damage of the device Packing list Before you start to install W PA please verify that your package contains the following items 1 x W PA SIP Public Announcer 1 x ground screw W PA Overview Front panel 1 PC interface connect the device to PC optional 2 Ethernet interface WAN PoE port it is recommended to use standard RJ45 interface 10 100M adaptive Ca...

Page 3: ...y interface connect switch components to this interface 5 Microphone interface it is recommended to use an electret condenser microphone sensitivity 38dB bias voltage 2 2V and connect it with a shielded cable to the grounding screw to improve anti interference 6 Switch input interface connect emergency switches door sensors and other switch components to this interface 7 Switch output interface co...

Page 4: ...he list of available devices and click Assign to user Enter the extension number of a user you want to assign the device to Public Announcer function via Intercom Paging Once the device is installed and configured you can use it as a Public Announcer for broadcasting purposes To broadcast a message via W PA First you need to set up a Dialplan to enable the device to answer calls automatically For ...

Page 5: ...4X0 Vision W AIR Handsets Android iOS apps W PA plays back simultaneously an amplified ringtone Factory reset In case you need to reconfigure your W PA you should perform a reset procedure To restart and restore the factory settings of W PA SIP Public Announcer Press the key with a paperclip and hold it for 3 seconds Reset Recovery procedure It is possible to perform recovery procedure for W PA Co...

Page 6: ... and Microphone interfaces 5 Connect a door release switch to Switch input interface 6 Connect an electric lock to Switch output interface Switch components configuration Configure Function keys to be able to place calls from to connected switch components Go to WMS Users Note W PA and Viking W 100 Handsfree Doorbox To use W PA with Viking W 1000 disconnect the circuit board and use 8 Ohm speaker ...

Page 7: ...boration Mobile app Use DTMF code 11 to open the door Press a Hang up button on the device you use for placing a call to hang up Unlocking doors with an outgoing call To unlock the door with an outgoing call from W PA Press the connected switch component for instance the door release switch A call will be placed to one of the extension numbers set up in section Function keys A user who receives a ...

Reviews: