Alarm Type
: The type of event that triggers an alarm. The options are: Disabled, Man Down,
No Movement, Running, Pull Cord, Emergency Button.
Alarm Signal
: Call. The alarm is made as an outgoing call to the emergency number
preconfigured for the extension.
Stop Alarm from Handset
: Enable/Disable. The possibility to cancel an alarm from the
handset.
Trigger Delay
: The timeout of pre-alarm warning. If set to 0, the alarm is sent immediately
(max. value is 255 sec.).
Note: For Man Down alarm, add the default delay of 6 seconds which is the time needed for the alarm
detection (e.g. if set to “0”, alarm is triggered after 6 sec, if set to “30”, alarm is triggered after 36 sec.)
Stop Pre-Alarm from Handset
: Enable/Disable the possibility to cancel the pre-alarm from the
handset.
Pre-Alarm Delay
: The timeout during which the pre-alarm warning is displayed until the
actual alarm is sent (max. value is 255 sec.)
Howling
: Enable/Disable the howling of the handset when the alarm is triggered.
After you have defined the Emergency profiles, click “Save” to apply.
7.4. Assign emergency profile to handsets
W-AIR Base Station (Multicell)
1. Go to the menu “Extensions”