background image

Wildix W-AIR system 3.80.x

Updated: 01/2016 
WMS version: 3.80.x 

Administrator’s Manual

Summary of Contents for W-AIR 3.80.x

Page 1: ...Wildix W AIR system 3 80 x Updated 01 2016 WMS version 3 80 x Administrator s Manual ...

Page 2: ... the Base Stations SB 11 3 3 Register deregister a Handset 12 3 4 Set up Repeaters 12 LEDs of the Repeaters 13 4 W AIR Network installation analysis W AIR Base Station Multicell 13 5 Technical Notes 14 5 1 Call Features DND Call Forward Call Waiting Ring tones 14 Ring tones 14 6 Upgrade Procedure of W AIR system 15 6 1 FW upgrade of Base Stations 15 6 2 FW upgrade of Repeaters and Handsets 15 Repe...

Page 3: ...ernet quality It combines telephony and Internet offering a great variety of new features The architecture consists of three simple components 1 Wildix W AIR Base Station left or Wildix W AIR Base Station Small Business SB right 2 Wildix W AIR Repeater 3 Wildix W AIR 150 W AIR 100 and Wildix W AIR 70 CAT iq cordless handsets System features 10 narrow band audio channels per base 4 CAT iq wideband ...

Page 4: ...connect up to 3 Repeaters to every Base station in their turn they can be connected to each other in chain of maximum 3 Repeaters Up to five users can communicate concurrently within the coverage range of every Repeater Features Up to 200 users per system Up to 40 bases maximum 39 slave bases registered to the master Up to 30 handsets registered to one base station Up to 3 Repeaters per base Up to...

Page 5: ...dBm value must be between 75 and 0 Base stations cannot be connected with the help of repeater W AIR Base Station Small Business SB To create a Wildix Small Business system it s enough to install one Small Business Base Station to which you can connect up to 3 repeaters Each system supports up to 8 cordless handsets Wildix W AIR System Administrator s Manual 3 80 x 5 ...

Page 6: ...honebook Loudspeaker Bluetooth Vibration Lonely worker alarms pull cord and alarm button IP65 W AIR 100 Features PRESENCE Remote phonebook Loudspeaker Vibration Belt clip W AIR 70 Features PRESENCE Remote phonebook Loudspeaker Belt clip case on demand code WAIR70 PC Compatible headsets https manuals wildix com headsets Wildix W AIR System Administrator s Manual 3 80 x 6 ...

Page 7: ...m Typically when the system is installed in the office buildings hotels or hospitals there should be both base stations and Repeaters on several floors to create uniform and complete radio coverage Open areas can be covered by wide network of Base stations In these applications the base stations and or Repeaters cover an extended range due to the extended line of sight radio propagation capability...

Page 8: ...ulti Cell to see the status and the coverage values of every connected base check the column DECT sync source to know the value Repeaters Go to the web interface of a base station and click on Repeaters to see the status and the coverage values of every connected Repeater check the column DECT sync source to know the value 2 3 Plan an installation Deployment Issues The following radio related issu...

Page 9: ...Base stations Simulate the worst environmental conditions close the doors turn on the equipment etc to perform a realistic test of configuration Call 98 code conference on your W AIR Handset to listen to the music on hold to test an audio reception quality Call 76 code echo on your W AIR Handset to test the voice quality Base station Repeater Placement Strategy The antennas of the base stations ar...

Page 10: ...Lighter types of construction materials require fewer base stations since attenuation figures are considerably lower 3 W AIR Network configuration 3 1 Provision base stations Note for W AIR Base Station Small Business SB Provisioning of Base Stations SB is possible only starting from the WMS Release 3 80 28622 08 Before provisioning of the Base Station SB it is necessary to upgrade the WMS to the ...

Page 11: ... field Code from the default one 0000 Repeaters will not work so it is recommended to keep the default Pin Code 4 Click Save Note The first devices becomes the Master of the network M The gateways make Radio sync with each other automatically to extend the work range if possible 5 Go back to the Devices Menu select your base bases and press Configure Sync device button LEDs of the Base Stations mu...

Page 12: ...0 then press Yes 3 4 Set up Repeaters 1 Find the IP of the base station that you want to repeat on the WMS devices list 2 Access the base station s web interface enter a username admin and a password that you can find in the WMS Devices menu in the Password field of the given base station 3 Select Repeaters in the menu and click on Add Repeater 4 Select Manually from the drop down menu if it is pr...

Page 13: ...st registration process LED blinks green during the connection process LED remains solid green when it is registered to a base station LED blinks green with a fast pulse when a phone connected to the Repeater starts a new call during the conversation it blinks red LED becomes solid red if the Repeater fails to connect to the base station 4 W AIR Network installation analysis W AIR Base Station Mul...

Page 14: ...User Settings or otherwise directly from the handset by dialing the Feature Codes of the system All the Call Features are synced with Wildix Collaboration Consult the WMS Dialplan Menu Feature Codes for details Ring tones Certain ring melodies are enabled by default for different call classes internal the melody selected in Ring melody menu of the handset external Melody 1 blacklist Melody 5 white...

Page 15: ...d in order to be able to perform the upgrade procedure Do not turn off or reboot repeaters manually during the upgrade they restart automatically Go to the Base Station interface menu Repeaters During the reboot you can see the progress of the upgrade of the repeaters in the field FWU Progress As soon as it s finished the FWU Progress displays Complete Handsets Note New FW is downloaded automatica...

Page 16: ...r several seconds Man Down Alarm The Man Down alarm is triggered if the handset remains in the position with an angle over 60 degrees with respect to the horizontal The time for the handset to be still before the alarm is triggered can be set on base station web interface read the next chapter 7 3 Set up emergency profiles No Movement Alarm To trigger the No Movement alarm the handset needs to be ...

Page 17: ...lt delay of 6 seconds which is the time needed for the alarm detection e g if set to 0 alarm is triggered after 6 sec if set to 30 alarm is triggered after 36 sec Stop Pre Alarm from Handset Enable Disable the possibility to cancel the pre alarm from the handset Pre Alarm Delay The timeout during which the pre alarm warning is displayed until the actual alarm is sent max value is 255 sec Howling E...

Page 18: ...ou can enter an extension number that must be called or customise the service by modifying the Dialplan in the WMS and to add the Alarm Number as a Called number into a Dialplan procedure 5 Tick off the Profiles that you wish to enable for this handset 6 Click Save on the bottom of the page 7 Go to Management menu and click Save and reboot to reboot the base station and apply the new parameters Wi...

Page 19: ...n the alarm is triggered from the handset Note You can enter an extension number that must be called or customise the service by modifying the Dialplan in the WMS and to add the Alarm Number as a Called number into a Dialplan procedure 5 Tick off the Profiles that you wish to enable for this handset 6 Click Save on the bottom of the page 7 Go to Management menu and click Save and reboot to reboot ...