Setup & Operation
Unpacking
Unpack the fixture and carefully inspect for any signs of physical damage. Report any damage to Wildfire or
your local distributor immediately. Included with each unit should be the following items:
1.
Twenty clamp, designed to attach the fixture to a 11/2” to 2” pipe truss
2.
Safety Cable, provided to secure the fixture when mounted on a pipe truss
3.
6’ Power Cable
4.
3’ USB Cable
5.
PowerCON 1 Power-Out Connector
6.
Operation Manual and Warranty Registration Card
Optional Accessories
Contact Wildfire or your local distributor for pricing on the following optional accessories:
1. 7.5” and 10” Barn Doors
2. 10° Spot Optic Set
3. 24° Spot Optic Set
4. 40° Spot Optic Set
Installation
The fixture is equipped with a yoke assembly for mounting. The yoke may be fitted with either a pipe clamp
(included) for mounting on a pipe truss or a baby bail block or junior pin for mounting on a light stand.
If the fixture is mounted on a pipe truss, be sure to use the included safety cable, looping it through the yoke
assembly and around the pipe truss. This will prevent the fixture from falling and possibly causing injury in the
event that the pipe clamp was not securely tightened.
To adjust the angle of the fixture, loosen the knobs on either side of the unit slightly, rotate to desired angle and
tighten. Care should be taken to support the front of the fixture while loosening the knobs to prevent the fixture
from rotating forward possibly causing injury.
The fixture comes standard with a 7.5” (VS-60) or 10” (VS-120) bracket assembly for attaching barn doors and
other accessories. When using accessories, be sure to attach the safety cable provided by the accessory
manufacturer to the fixture yoke assembly.
Plug the fixture into the appropriate power source. If you are controlling the fixture with a lighting control board,
you will need to make sure it is plugged into a non-dim circuit. If the fixture is plugged into a dimmable circuit, it
will not operate.
Local Mode Operation
To operate the fixture in local mode, turn the fixture ON by pushing the power/breaker switch to the ON position.
Set the Control Source menu selection to “Local.” Set the Dimmer menu selection to the desired output level (0
– 100%). Set the Effect menu selection to the effect you want.
Effects Settings:
Setting
Function
Description
OFF
No Effects
All LED's static at the brightness set on the Dimmer setting
Strobe 1-60
Strobe
Adjustable strobe of all LED's at the brightness set on the Dimmer setting
Flash 1-60
Flash
Adjustable flash of all LED's at the brightness set on the Dimmer setting
Pulse 1-60
Pulse
Adjustable pulse of all LED's at the brightness set on the Dimmer setting
Random 1-66
Random
Adjustable random strobe of all LED's at the brightness set the Dimmer setting
5