![Wilden T2 Original Metal Manual Download Page 8](http://html1.mh-extra.com/html/wilden/t2-original-metal/t2-original-metal_manual_980905008.webp)
6
Height .................................. 279 mm (11.0”)
Width ................................... 267 mm (10.5”)
Depth .................................... 185 mm (7.3”)
Est. Ship Weight .........Aluminum 12 kg (26 lbs)
Stainless Steel 16 kg (36 lbs)
Air Inlet ...................................... 6 mm (1/4”)
Inlet ............................................ 25 mm (1”)
Outlet ......................................19 mm (3/4”)
Suction Lift ......................... 5.18 m Dry (17’)
9.45 m Wet (31’)
Displacement per
Stroke ....................... 0.41 l (0.105 gal.)
1
Max. Flow Rate ................. 132 lpm (35 gpm)
Max. Size Solids .....................3.2 mm (1/8”)
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 68.1 lpm (18.0 gpm)
against a discharge pressure head of 2.7 bar
(40 psig) requires 4.1 bar (60 psig) and
18.7 Nm
3
/h (11 scfm) air consumption. (See
dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
Height .................................. 279 mm (11.0”)
Width ................................... 267 mm (10.5”)
Depth .................................... 185 mm (7.3”)
Est. Ship Weight .........Aluminum 12 kg (26 lbs)
Stainless Steel 16 kg (36 lbs)
Air Inlet ...................................... 6 mm (1/4”)
Inlet ............................................ 25 mm (1”)
Outlet ......................................19 mm (3/4”)
Suction Lift ........................... 1.52 m Dry (5’)
9.45 m Wet (31’)
Displacement per
Stroke ....................... 0.41 l (0.105 gal.)
1
Max. Flow Rate ................. 132 lpm (35 gpm)
Max. Size Solids .....................3.2 mm (1/8”)
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 60.6 lpm (16.0 gpm)
against a discharge pressure head of 2.7 bar
(40 psig) requires 4 bar (60 psig) and
17 Nm
3
/h (10 scfm) air consumption. (See dot
on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
SECTION 5B
PERFORMANCE CURVES
SECTION 5A
PERFORMANCE CURVES
T2 METAL RUBBER-FITTED
T2 METAL TPE-FITTED
WILDEN PUMP & ENGINEERING, LLC
WIL-10200-E-03