WIL-10183-E-04
22
P4 Clamped Metal
Carefully prepare sealing surfaces by removing all debris and foreign matter from diaphragm bead and all mating surfaces. If necessary, smooth or
deburr all sealing surfaces. Mating surfaces must be properly aligned in order to ensure positive sealing characteristics.
Step 1
Step 2
Step 3
Gently remove the adhesive covering from
the back of the PTFE tape. Ensure that the
adhesive strip remains attached to the
PTFE tape.
Starting at any point, place the PTFE tape in
the center of the diaphragm bead groove on
the liquid chamber and press lightly on the
tape to ensure that the adhesive holds in
place during assembly. Do not stretch the
tape during placement in the center of
diaphragm bead groove.
The end of the tape should overlap
approximately 13 mm (1/2"). Proceed to
install the PTFE tape on the remaining
diaphragm.
GASKET KIT INSTALLATION