![Wilden P4 series Operation & Maintenance Manual Download Page 10](http://html.mh-extra.com/html/wilden/p4-series/p4-series_operation-and-maintenance-manual_980878010.webp)
WIL-10183-E-04
10
P4 Clamped Metal
P4 METAL
ULTRA-FLEX
TM
-FITTED
Ship Weights………….Aluminum 13 kg (29 lb)
Stainless Steel 20 kg (45 lb)
Cast Iron 22 kg (49 lb)
Alloy C 23 kg (51 lb)
Air Inlet……………………..……..19 mm (3/4")
Inlet…...…………………...…….38 mm (1-1/2")
Outlet………………...………….32 mm (1-1/4")
Suction Lift…………...…………5.2 m Dry (12’)
8.5 m Wet (28’)
Disp. per Stroke
1
……...…......0.76 L (0.20 gal)
Max. Flow Rate……………..269 lpm (71 gpm)
Max. Size Solids……………….4.8 mm (3/16")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 170 lpm (45 gpm) against a
discharge pressure head of 2.0 bar (30 psig)
requires 4.1 bar (60 psig) and 85 Nm
3
/h (50
scfm) air consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.