background image

Complexity

Operating 

costs

Wildeboer-Net

Operating 

principle 

Test

Cold 

smoke

The solution:

Wildeboer Bauteile GmbH

Marker Weg 11

 

|

 

26826 Weener (Germany)

 

|

 

 

+49 4951 950-0

 

|

 

 

+49 4951 950-27120

 

[email protected]

 | 

 

www.wildeboer.de

Watch explanatory video 

on YouTube

wildeboer.de/youtube

Network  your  fire  protection  and  significantly  minimise  the  cost  of 

planning,  installation  and  testing.  The  BS2  communication  system 

“Wildeboer-Net”  lays  all  the  groundwork  for  you.  Don’t  miss  out  on 

these benefits. We would be glad to advise you.

BS2 communication system 

“Wildeboer-Net”

 

ƒ

Optimum system solution combined with 

our maintenance-free fire dampers

The system design, installation, programming and 

commissioning of conventional control systems in 

buildings is complex.

Special plug-and-play functionality allows control 

 

systems for fire dampers to be designed, built and 

connected in parent hierarchy without any measuring 

 

and control know-how.

Preventing smoke spreading is a challenge.

Detect smoke and close fire dampers reliably and in good 

time via flexible release groups. 

Recurring functional tests are time-consuming, affect 

operation and incur high costs.

The BS2 communications system “Wildeboer-Net” performs 

functional testing in less than 10 minutes in all.

Fire dampers have to operate reliably. Changes in the 

building control system always require new operating 

principle testing.

The BS2 communication system “Wildeboer-Net” controls 

and safeguards the functioning of fire dampers. Changes 

in the building control system have no effect.

BS2 communication system “Wildeboer-Net”

Our response:

Existing problems:

Summary of Contents for FK90

Page 1: ...series FK120 Heights up to 1000 mm Fire resistance period up to 120 minutes Fire classification EI 30 60 90 120 ve ho i o S C10ooo Hygiene certificate Environmental Product Declaration according to IS...

Page 2: ...arge free cross section Maximum volume flows Minimum pressure drop Extremely low sound power level Connection holes for profiles from 20 mm in height Two control openings inspection openings for viewi...

Page 3: ...tability free dom of damper blade movement minimum pressure drop and low noise level Option Casing with epoxy resin powder coating Replaceable damper blade made of high temperature re sistant corrosio...

Page 4: ...ld smoke extraction are country specific Electric spring return actuators also close the fire dampers if the supply voltage is interrupted They reopen the fire dampers as soon as the voltage is presen...

Page 5: ...n ded and vertical positions on site Terminal box FK90 fire dampers Release mechanisms and actuators 2 Thermal mechanical release mechanism with 70 C release element Option with coated 70 C release el...

Page 6: ...ocations must not be changed on site H J3 K K400 K500 200 170 225 160 250 145 275 135 4 300 120 17 325 110 29 350 95 42 375 85 54 400 70 67 450 45 92 500 20 117 17 550 142 42 600 7 167 67 650 32 192 9...

Page 7: ...637 0 684 0 780 0 876 1050 0 117 0 142 0 167 0 192 0 217 0 268 0 318 0 368 0 418 0 469 0 519 0 569 0 620 0 670 0 720 1100 0 122 0 149 0 175 0 202 0 228 0 281 0 334 0 386 0 439 0 492 0 545 0 598 0 650...

Page 8: ...m m 0 0 5 1 B 1 2 0 0 M e t a l d a m p e r b l a d e B 1 5 0 0 m m 1 4 0 0 v 12 m s A Volume flow m h v 12 m s A Operating pressure User Manual 5 0 2 2016 10 8 Subject to change Series FK120 FK90 fir...

Page 9: ...400 800 500 600 Width B mm 200 250 300 350 400 500 600 700 800 Height H mm Volume flow V m h 225 275 200 300 400 600 800 1000 2000 3000 4000 6000 8000 10000 20000 30000 40000 50000 150 900 1000 900 10...

Page 10: ...Afree 0 098 m Dps 29 Pa vA 7 4 m s LWA 47 dB A Sound power level LW Oct for the octave mid frequencies f Hz 63 125 250 500 1000 2000 4000 8000 LWA dB A 47 47 47 47 47 47 47 47 DL7 4 m s dB 5 6 1 3 6...

Page 11: ...always located to the H side on the casing of the fire dampers see page 6 FK90 fire dampers Installation in rigid walls and ceilings and in metal stud walls 1 with cladding on both sides The fire damp...

Page 12: ...rete in solid construction Rigid walls and ceilings must have bulk density 450 kg m Metal stud walls should be clad on both sides in two or more layers with 12 5 mm GKF plasterboard Installation openi...

Page 13: ...nd tested periodically to ensure they are functioning correctly The intervals largely depend on the system operation Rele vant regulations should be followed FK90 fire dampers series FK120 are mainten...

Page 14: ...Option Explosion protected limit switch EX CLOSED EX OPEN Option Electric actuators M220 9 V M24 9 V M220 7 M24 7 Option Electric explosion protected actuators EM 1 RM 1 EM 2 see pages 5 and 6 FK90 f...

Page 15: ...metal stud walls Enclosed maintenance free thermal release mechanism 70C 95 C or 100 C for manual single handed operation corrosion resistant release element with two electrical limit switch es for s...

Page 16: ...nventional control systems in buildings is complex Special plug and play functionality allows control systems for fire dampers to be designed built and connected in parent hierarchy without any measur...

Reviews:

Related manuals for FK90