GEMINI IF BREWER

SATELLITE

UCM CONTROL

IF CONNECTOR

INTELLIFRESH FUNCTION & FEATURES

WARNING: 

AVOID SCALDING, Do not remove brew cone while brew light is flashing.

1.  Brewer should be ON. Confirm this at rear toggle switch, then press the ON/OFF button on the UCM (Universal Control Module). Ready-to-

Brew should be on the display. If the brewer is connected to an InterLock grinder, the grinder should be on. When Interlock connection is 

made, grind coffee at this time.

2.  Position an empty Satellite onto the brew deck.

NOTE: Only use Intellifresh Satellites on Intellifresh Brewers.

6.  Press appropriate 

brew button.  

Brewing will begin 

immediately.

5.   Transfer filled brew 

cone to brewer.

3.  Place a clean filter 

into the brew cone.

4.   Fill brew cone with 

appropriate amount 

of ground coffee.

INTELLIFRESH BREWING INSTRUCTIONS

The IntelliFresh system will alert you when the coffee has exceeded the desired hold-

ing time. The Intellifresh system is activated by a connector on the Satellite connecting 

to the corresponding connector on the center panel. IntelliFresh is adjustable through 

the UCM controller on the brewer. 

Quality Timer

 (Factory Set to 2 hours)

Press 

¤

 to select, press < or > to choose the desired setting. Range 20 min. to 240 

min.  The timer is intended to notify the user when the coffee loses its freshness.  The 

indicator light (LED) on the satellite will remain solid red until the Quality Timer expires 

(Factory Set to 2 hours).  At expiration the LED will flash and remain flashing at the 

factory setting for an additional 8 hours.  The additional 8 hours is controlled by the 

Warmer Auto-Off setting (see below Warmer Auto Off).

•  Setting Range:  20 – 240 minutes. The default time is 2 hours.
•  Time Expiration Indicator:  LED flashes after expiration of Quality Timer Setting 

for up to a total of 12 hours.  The default time is 8 hours after expiration of the 

Quality Timer. 

Warmer Auto-Off 

(Factory set to 10 Hrs.)

Press 

¤

 to select < or > to adjust from 1-12 

hours.  This feature has higher priority than the 

Quality Timer.  It shuts off the warmers after a 

pre-determined time (factory set at 10 hours) 

starting when the Brew Button is pushed.  The 

Quality Timer does not affect this function.

Summary of Contents for Gemini IntelliFresh GEM3IF

Page 1: ...n Use tubing sized sufficiently to provide a minimum of 1 0 GPM 2 Connect the unit to an appropriate electrical power circuit 3 Turn on the toggle STANDBY ON switch behind the unit The heating tank wi...

Page 2: ...necting to the corresponding connector on the center panel IntelliFresh is adjustable through the UCM controller on the brewer Quality Timer Factory Set to 2 hours Press to select press or to choose t...

Page 3: ...ately 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen It takes approximately 20 minutes to reach setpoint temperature of 200 F Control will display...

Page 4: ...Cold Brew Lock Factory set to 5 Press to select or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the...

Page 5: ...DIUM 132oz 4oz SMALL 64oz 4oz Press to Select Display will ask you to select a brew button Large Medium or Small Press the desired brew button to begin when desired volume is reached press the same br...

Page 6: ...ctions are ThermoPro Twin ThermoPro Single Gemini Twin Gemini Single Milano Twin Milano Single Gemini Twin IF and Gemini Single IF Press to set When the Model Select feature is changed all settings ar...

Page 7: ...7 GEMTIF Rough In Drawings GEMSIF...

Page 8: ...8 1 2 3 4 5 32 19 6 7 8 9 10 11 12 42 13 39 15 17 18 43 44 45 20 21 22 30 31 25 26 23 27 24 28 29 33 34 35 41 36 46 5 37 16 14 40 38 47 Illustrated Parts List GEMTIF...

Page 9: ...AT SINK BREW CONE ASSY W SPLASH POCKET BROWN COFFEE LABEL BOTTOM PANEL COVER FRONT WELD ASSEMBLY SS COVER FRONT WELD ASSEMBLY BLACK POWDER COAT HOLDER IF CONNECTORS FEMALE GEMTIF LABEL WARNING SHOCK H...

Page 10: ...10 Electrical Schematic GEMTIF...

Page 11: ...11 5 6 7 8 9 10 11 12 14 40 36 16 17 18 19 20 21 22 25 23 24 26 27 28 29 30 31 32 33 1 2 43 3 4 34 37 38 39 42 7 13 15 35 Illustrated Parts List GEMSIF...

Page 12: ...NK GASKET TANK LID KIT PROBE ASSY WATER LEVEL W FITTING O RING NUT TANK COMPLETE GEMSS W ULTEM FITTINGS KIT ELEMENT HEATING 1 6KW120V W JAM NUT WASHERS SENSOR HEATING TANK GUARD SHOCK HEATING ELEMENT...

Page 13: ...13 Electrical Schematic GEMSIF 10 Only...

Page 14: ...14 2 3 4 5 6 1 7 11 10 12 13 16 18 19 8 9 14 20 15 17 A Illustrated Parts List GEM3IF...

Page 15: ...AP SHIELD W VENT WASHER SHIELD CAP 1 8 GLASS GAUGE 8 SHIELD GAUGE GLASS D x 8 WASHER 188ID x 188 THK BOTTOM GAUGE GLASS ASSEMBLY 8 LABEL SIDE GEM3IF CURTIS LOGO BRACKET GAUGE GLASS GEM 3 GUARD FAUCET...

Page 16: ...ION DO NOT use undiluted bleach or chlorine 1 Turn off the unit at the button on the front control panel 2 Wipe exterior surfaces with a damp cloth removing spills and debris 3 Slide the brew cone out...

Page 17: ...If okay then leave the seat cup attached on the handle bonnet assembly Soak then wipe clean Replace the seat cup if damaged 7 Remove the gauge glass tube by unscrewing the gauge glass cap 8 Clean the...

Page 18: ...a professional technician and must comply with all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied wit...

Reviews: