Mount  the flexible tube and tighten the parallel compression fitting. Put the 
sensor into the sensor pocket as far as it will go. Screw carefully the cable 
sheet on the sensor pocket. 
 
Attention:  The  collector  temperature  sensor  is  not  part  of  the  in  roof 
mounting kit but part of the controller. 

 

Position 2

 

clamp and spacer brackets between the collectors and the upper 

and  lower  side  of  each  collector  and  screw  it  on  the  batten  with  wooden 
screws 6x60 mm (Pos. 2). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Before  installing  further  flashings,  the  collectors  should  be  pressure 
tested with 6 bar independently from the rest of the solar system! 
 
 
 
 
 
 

 
 
 
 

 

 

Position the left side flashing from the side on the collector and nail it with 3 fixing hooks onto the batten.  Repeat the same 
procedure with the right collector and the right side flashing.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Bend the long center flashing up and slide it down between the collectors. Bend the lower flashing lip and push it under the 
collector.

 

 

 

 

 

 

Summary of Contents for Wikosun 2020-Mi

Page 1: ...ations Factory warranty will only be covered if the installation instructions are followed Warranty does not cover any damages caused by non observance of this manual The correct functioning is only g...

Page 2: ...6 7 8 Collector 2020 Mi 2340 Ti Clamp and positioning clip U shape Parallel compression fitting 22mm Compression T fitting 22x22x1 2 collector flow hot Sensor pocket x 100mm with cable bushing Compres...

Page 3: ...flow hot 1 Sensor pocket x 160mm with cable bushing 1 ST AVS 1S Compression fittings 22 x 22 mm 2 Flexible tube kit ST ADF 1 Flexible stainless steel tube with Cu joints 22mm 2 Chart 2 Mounting acces...

Page 4: ...ctors must be sufficiently stable If the distance between the battens or the rafters is too big additional battens should be inserted Number of collectors 2 3 4 Width of collector field mm 2950 4075 5...

Page 5: ...ld be put with the folded edge on the upper edge of the main batten Position the hanger support brackets distance between the hanger support brackets of ca 80 cm und pre drill the lower flashing Screw...

Page 6: ...en the collectors and the upper and lower side of each collector and screw it on the batten with wooden screws 6x60 mm Pos 2 Before installing further flashings the collectors should be pressure teste...

Page 7: ...distance of the battens an auxiliary batten must be installed for the mounting of the upper flashing in order to support the center flashing Position the upper flashings over the side flashings Secure...

Page 8: ...f adhesive sealing strips and position sealing cover Press down sealing cover and strip into position Then secure strip with screw and fiber washer supplied and fold sealing strip over flashings Cover...

Page 9: ...ly purged Open the lower plug at the collector field to purge the system Subsequently the system is to be filled with a water antifreeze mixture Please refer to chapter 7 Antifreeze for it s preparati...

Page 10: ...length of 40 m and heat exchangers with a capacity of 16 l Number of collectors 2 3 4 5 6 7 8 9 10 External diameter of the connection pipe in mm Flow rate in l min Flow rate in l h Expansion vessel i...

Page 11: ...no need of changing the preset parameters Please do not change the preset parameters by yourself You will lose any warranty and guarantee claim If you do not conform to the preset parameters please le...

Page 12: ...led sole Color medium 1 uncolored brown black cloudy 2 uncolored brown black cloudy 3 uncolored brown black cloudy 4 uncolored brown black cloudy 5 uncolored brown black cloudy 6 uncolored brown black...

Page 13: ...It is not hazardous material in the sense of transport regulations Gaseous state Color Odor Boiling point Density pH value Viscosity Water solubility Specific humidity Responsiveness Flashpoint Explos...

Page 14: ...authority in charge Cleaning clean with liquid binding material sand kieselguhr acid binder or universal binder Recycle contaminated material separately Keep the concentrate in a cool and dry environ...

Page 15: ...writing within 10 days after receipt or hidden defects immediately after emerging In case of hidden defects it is only valid for the warranty exceeding the legal warranty period if the collectors are...

Page 16: ...k vent valve at collectors Primary pressure exp vessel C Type Cooling function from colour unchanged brown black cloudy Flow rate m System settings Controller setting Consumer 1 e g DHW Consumer 2 e g...

Page 17: ...llector fastening is stable User has been instructed Maintenance contract Operation of pumps checked Temperature sensores indicate realistic values Collector interior is not fogged Collector is clean...

Reviews: