background image

© Wikora GmbH 

Page 1  

      As of November 2013 

 

 

      Errors excepted. 

 

WIKORA GmbH 

Friedrichstr. 9 

89568 Hermaringen 

Phone: (07322) 9605-0 

Fax: (07322) 9605-30 

email: [email protected] 

 
 
 

Installation manual 
Operating instructions

 

Solar combi tank 
with DHW heat exchanger

 

 
 

 

 

WIKOSOL TWIN TRIVALENT 

 

Installation 

and 

commissioning 

must 

be 

undertaken by a specialist. 

General terms and conditions of warranty state that 
all  installations  must  be  carried  out  by  a  suitably 
trained  and  qualified  plumber  who  observes  the 
local norms and regulations. 

The  installation  and  maintenance  record  must 
be  entirely  completed  and  the  user  has  to  be 
instructed accordingly.  

Efficient  operation  can  only  be  guaranteed  if  the 
instructions of this manual are followed.  
Warranty  does  not  cover  any  damage  caused  due 
to non-observance of this manual and the technical 
rules in force. 
The  system  is  to  be  checked  annually  by  a 
specialized company. In addition, occurring defects 
must be repaired immediately. 
 

This  document  should  be  handed  over  to  the 
client on completion of the installation. 
 

 

Index 

General ................................................................................................................................................................................... 2 

Transport and installation ....................................................................................................................................................... 2 

Dimensions and connections .................................................................................................................................................. 3 

Technical data ........................................................................................................................................................................ 4 

Installation .............................................................................................................................................................................. 5 

Commissioning ....................................................................................................................................................................... 6 

Maintenance and wear parts .................................................................................................................................................. 6 

Warranties and guarantee ...................................................................................................................................................... 7 

Installation record ................................................................................................................................................................... 8 

 
 
 
 

 

Summary of Contents for WIKOSOL TWIN TRIVALENT

Page 1: ...tion and maintenance record must be entirely completed and the user has to be instructed accordingly Efficient operation can only be guaranteed if the instructions of this manual are followed Warranty...

Page 2: ...be longer than 2 m If for any compelling reasons 3 bends or a length up to 4 m are required then the entire exhaust line must be designed one nominal size larger More than 3 bends or a length exceedi...

Page 3: ...2 552 1630 832 157 Wikosol Twin Trivalent 800 790 990 1357 1797 2023 1962 1032 282 1107 832 282 1382 602 2030 977 157 Chart 1 W Tilting dimension Connections Type Wikosol Twin Trivalent 600 Wikoso Twi...

Page 4: ...er bar 3 10 16 3 10 16 Capacity of solar heat exchanger litre ca 14 ca 16 Surface coaxial heat exchanger internal tube heating water m 1 7 1 7 Surface coaxial heat exchanger piston ring DHW m 2 8 2 8...

Page 5: ...e pipes When connecting to a solar plant a temperature limiter is required and must be installed on site at the hot water outlet in order to prevent scalding The minimum rate of flow for the charge pu...

Page 6: ...nozzles again Start up the heating system While the System is heating up water will leak out of the safety valve Before the handover of the system to the end user owner the plumbing contractor should...

Page 7: ...has been modified through the installation of externally supplied parts or through irregular professional maintenance Subject to our general terms and conditions Legal warranty 2 years Guarantee year...

Page 8: ...operation and maintenance Place Date Customer Installer Signature Signature Place of installation Name ZIP Code Place Street Phone Tank model Serial number Date of invoice In the case of reclamation...