WIKA operating instructions model TG58SA
■
The welding sockets shall comply with EHEDG documents doc. 9
and doc. 35. With TIG welding, the surface quality must be R
a
≤ 0.8
µm. The weld seams must be free from defects on the wetted and
non-wetted contact sides and must be butt welded.
■
For tank-mounted temperature measuring instruments the tank
cleaning devices shall be positioned in such a way that the instrument
can be assessed and is perfectly cleaned. Avoid spray shadows
during CIP cleaning.
Special instructions for in-line versions
■
In-line access units (e.g. VARINLINE
®
) and instrumentation T-pieces
in horizontal pipes should be installed with a slight pipe inclination for
self-draining.
■
With in-line access units (e.g. VARINLINE
®
), use the original seals
from the manufacturer and observe their installation instructions.
■
Specify the insertion length so that the active part of the sensor is
placed in the middle of the flow.
■
Specify the insertion length so that no collision or contact can occur
with sensors installed opposite.
5.2 Zero point setting
Zero point setting can be made with a slotted screwdriver or open-ended
spanner at the back of the case, as shown.
5. Commissioning, operation
Summary of Contents for TG58SA
Page 22: ...EN 14399932 01 06 2022 EN DE FR ES 22 WIKA operating instructions model TG58SA ...
Page 42: ...14399932 01 06 2022 EN DE FR ES 42 WIKA operating instructions model TG58SA ...
Page 62: ...FR 14399932 01 06 2022 EN DE FR ES 62 WIKA mode d emploi type TG58SA ...
Page 82: ...ES 14399932 01 06 2022 EN DE FR ES 82 WIKA manual de instrucciones modelo TG58SA ...
Page 83: ...WIKA operating instructions model TG58SA 14399932 01 06 2022 EN DE FR ES 83 ...