5. Commissioning, operation
Sealing variants
5.4 Electrical mounting
5.4.1 Requirements for voltage supply
→ For power supply see product label
The power supply for the pressure switch must be made via an energy-limited electric circuit in accordance with
section 9.4 of UL/EN/IEC 61010-1, or an LPS per UL/EN/IEC 60950-1 / CSA C22.2 no. 60950-1, or class 2 in
accordance with UL1310/UL1585 (NEC or CEC). The voltage supply must be suitable for operation above 2,000 m
should the pressure switch be used at this altitude.
5.4.2 Requirements for electrical connection
■
Ingress protection of the mating connector corresponds to the ingress protection of the pressure switch.
■
Cable diameter matches the cable bushing of the mating connector.
■
Cable gland and seals of the mating connector are correctly seated.
■
No humidity can ingress at the cable end.
Parallel threads
Seal the sealing face
with flat gasket,
lens-type sealing ring or WIKA profile
sealing.
per EN 837
per DIN EN ISO 1179-2
(formerly DIN 3852-E)
Tapered threads
Wrap threads with sealing material
(e.g. PTFE tape).
NPT, R and PT
Summary of Contents for PSD-4-ECO
Page 36: ...14247391 01 07 2019 EN DE FR ES 36 WIKA operating instructions model PSD 4 ECO EN ...
Page 70: ...14247391 01 07 2019 EN DE FR ES 70 WIKA Betriebsanleitung Typ PSD 4 ECO DE ...
Page 104: ...14247391 01 07 2019 EN DE FR ES 104 Mode d emploi WIKA type PSD 4 ECO FR ...
Page 138: ...14247391 01 07 2019 EN DE FR ES 138 WIKA manual de instrucciones modelo PSD 4 ECO ES ...
Page 139: ...14247391 01 07 2019 EN DE FR ES 139 WIKA manual de instrucciones modelo PSD 4 ECO ES ...