19
WIKA operating instructions pressure sensor, model O-10
EN
11613017.05 09/2019 EN/DE/FR/ES
3. Specifications
3.14 Electrical connections model O-10 (T)
Available connections
Electrical connection
Ingress
protection
Wire cross-
section
Cable
diameter
Cable
lengths
Angular connector DIN 175301-803 A
IP65
-
-
-
Angular connector DIN 175301-803 C
IP65
-
-
-
Circular connector M12 x 1 (4-pin)
IP67
-
-
-
Metri-Pack series 150
1)
IP67
-
-
-
Cable outlet, unshielded
2)
IP67
0.14 mm
2
3.4 mm
2 m, 5 m
Cable outlet, shielded
IP67
0.14 mm
2
4.3 mm
2 m, 5 m
1) for model O-10 (T) only possible from measuring range 0 ... 60 bar
2) up to a maximum of 80 °C permitted
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors that have the
appropriate ingress protection.
Short-circuit resistance
S+ vs. 0V
Reverse polarity protection
UB vs. 0V
Overvoltage protection
DC 36 V
Insulation voltage
DC 750 V