![WIKA IPT-2 Series Operating Instructions Manual Download Page 46](http://html1.mh-extra.com/html/wika/ipt-2-series/ipt-2-series_operating-instructions-manual_980233046.webp)
46
9 Supplement
WIKA Operating Instructions - Process pressure transmitter IPT-2x
9 Supplement
9.1 Technical data
Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
Materials and weights
Materials, wetted (piezoresistive/strain gauge measuring cell)
Process fitting
316L
Diaphragm standard
316L
Diaphragm from measuring range 25 bar,
with not flush version
Elgiloy (2.4711)
Seal ring, O-ring
FKM (VP2/A), EPDM (A+P 70.10-02), FFKM (Perlast
G75S), FEPM (Fluoraz SD890)
Seal for process fitting (in the scope of delivery)
Ʋ Thread G½ (EN 837)
Klingersil C-4400
Materials, wetted (ceramic/metallic measuring cell)
Process fitting
316L
Diaphragm
Alloy C276 (2.4819), gold-coated 20 µ, gold/rhodium-
coated 5 µ/1 µ
5)
Seal for process fitting (in the scope of delivery)
Ʋ Thread G1½ (DIN 3852-A)
Klingersil C-4400
Ʋ Thread M44 x 1.25 (DIN 13)
FKM, FFKM, EPDM
Materials for applications in foodstuffs
Surface quality, hygienic process fittings,
typ.
R
a
< 0.8 µm
Seal below wall mounting plate with 3A
approval
EPDM
Materials, non-wetted parts
Type label support on connection cable PE hard
Isolating liquid ceramic/metallic measur-
ing cell
KN 92 medical white oil (FDA conform)
Internal transmission liquid piezoresistive
measuring cell
Synthetic oil, Halocarbon oil
6)7)
Housing
Ʋ Plastic housing
Plastic PBT (Polyester)
5)
Not on instruments with SIL qualification.
6)
Synthetic oil for measuring ranges up to 40 bar, FDA listed for the food processing industry. For measuring
ranges up to 100 bar dry measuring cell.
7)
Halocarbon oil: Generally in oxygen applications, not with vacuum measuring ranges, not with absolute meas-
uring ranges < 1 bar
abs
.