11325232.05 09/2016 EN/DE/FR/ES
10
WIKA operating instructions DiwiTherm
®
, model TR75
EN
4.1.2 DiwiTherm
®
for mounting in a thermowell
Sensor
Material: stainless steel
The sensor is made from vibration-resistant, sheathed cable (MI cable).
The sensor diameter should be approx. 1 mm smaller than the bore diameter of the
thermowell. Gaps of more than 0.5 mm between thermowell and the sensor will have a
negative effect on the heat transfer, and they will result in unfavourable response behaviour
of the thermometer.
When fitting the measuring insert into a thermowell, it is very important to determine the
correct insertion length (= thermowell length for bottom thicknesses of ≤ 5.5 mm). In order to
ensure that the sensor is firmly pressed down onto the bottom of the thermowell, the sensor
must be spring-loaded (spring travel: max 10 mm).
Process connection (standard process connection)
Material: stainless steel
Threaded connection: G ½ B
M14 x 1.5
M18 x 1.5
½ NPT
Union nut:
G ½ B
Male nut:
G ½ B
Neck tube
Material: stainless steel
Neck tube diameter: 12 mm
Standard neck length: 150 mm
others on request
(minimum neck length: 30 mm)
Sensor lengths
Sensor Ø
in mm
Standard insertion lengths A (l
1
) in mm
3
110 140 145 170 200 205 230 245 260
294
305 345 350
395
410 445 545
6
-
-
-
170 200 205 230 245 260
295
305 345 350
395
410 445 545
8
-
-
-
-
200 205 230 245 260
295
305 345 350
395
410 445 545
Special lengths are possible.
4. Design and function
Summary of Contents for DiwiTherm TR75
Page 24: ...11325232 05 09 2016 EN DE FR ES 24 WIKA operating instructions DiwiTherm model TR75 EN ...
Page 66: ...66 WIKA mode d emploi DiwiTherm type TR75 FR 11325232 05 09 2016 EN DE FR ES ...
Page 87: ...WIKA operating instructions DiwiTherm model TR75 87 11325232 05 09 2016 EN DE FR ES ...
Page 88: ......