12
WIKA operating instructions digital pressure gauge, model DG-10
11250313.03 09/2012 GB/D/F/E
GB
For special model numbers, e.g. DG-10000, please note the specifications stated on the delivery note.
For further specifications see WIKA data sheet PE 81.66 and the order documentation.
3.7 Operating conditions
Ingress protection (per IEC 60529)
IP 65
Temperatures
■
Medium:
- Measuring range < 100 bar: -30 ... +85 °C
- Measuring range ≥ 100 bar: -30 ... +100 °C
■
Ambient:
-10 ... +60 °C
■
Storage:
-20 ... +70 °C
3.8 Materials
Wetted parts
■
Process connection:
Stainless steel 1.4571
■
Sensor element ≤ 50 bar:
Ceramic Al2O3 96 %
NBR (option: EPDM)
■
Sensor element > 100 bar: XM-13 (stainless steel 1.4534)
Non-wetted parts
■
Case:
Stainless steel 1.4301
■
Front foil and membrane: Polyester
3. Specifications