WIKA data sheet CT 15.51 ∙ 03/2019 

Page 8 of 15

Dimensions in mm (in)

Reference pressure sensor 

model CPT7000

Digital process calibrator model CPH7000

Summary of Contents for CPH7000

Page 1: ...smitter via the electrical module and to measure or also simulate its output signal Functions The calibrator offers the possibility to set calibration routines quickly and easily but also to run preconfigured calibration routines and automatically save the measured values Over the WIKA Wireless interface the completed calibration processes can be transmitted to a PC This data can subsequently be e...

Page 2: ...calibrator model CPH7000 Display Display Touchscreen colour display Display resolution up to 5 digits selectable Pressure units mbar bar psi Pa kPa hPa MPa mmHg cmHg inHg mmH2O mH2O inH2O 4 C inH2O 20 C inH2O 60 F inHg 0 C inHg 60 F kg cm kp cm lbf ft kN m atm Torr micron g l 20 C kg m 20 C as well as two user defined units Settings Applications Apps Measure calibrate logger switch test Measuring ...

Page 3: ...y Measure 0 01 1 µA Supply 0 01 2 µA 8 Voltage Measuring input DC 0 30 V Measuring output DC 24 V Resolution 1 mV Accuracy 0 01 or reading 1 mV Barometric reference 1 9 Measuring range 850 1 100 mbar 12 3 16 psi Accuracy 1 mbar 1 Optional 5 The internal reference sensor is only available in combination with a pneumatic unit 6 It is defined by the total measurement uncertainty which is expressed wi...

Page 4: ...obe diameter 3 mm 0 12 in Cable length 1 m 3 28 ft Connection to CPH7000 max 1 temperature probe 2 User defined RTD probe Input of the coefficients of R0 A B and C Ambient module 1 Measuring range Air humidity 0 100 r h Temperature 30 125 C 22 257 F Accuracy Air humidity 5 r h Temperature 0 2 K 0 36 F Connection to CPH7000 max 1 ambient module 2 WIKA Wireless 4 Frequency range 2 400 2 500 MHz HF o...

Page 5: ... times 1 600 bar 1 1 times 6 000 bar 3 times 360 psi 2 times 360 psi 8 700 psi 1 5 times 8 700 psi 25 000 psi 1 3 times 25 000 psi 1 1 times 85 000 bar Process connection Selectable versions G B G B G female G B G male on G female G B flush with O ring of NBR G B flush with O ring of EPDM G 1 B flush with O ring of NBR G 1 B flush with O ring of EPDM NPT NPT NPT male on NPT female NPT female M16 x...

Page 6: ...r 9 84 ft connection cable plug and play Ingress protection IP65 IP67 when connected Dimensions see technical drawing Weight approx 230 g 0 5 lbs 11 For oxygen versions the medium temperature must not exceed 60 C 140 F Approvals Logo Description Country EU declaration of conformity for CPH7000 EMC directive EN 61326 emission group 1 class B and interference immunity portable measuring equipment R ...

Page 7: ... Uzstandard 12 Metrology measurement technology Uzbekistan 12 Optional Certificates Certificate Calibration Standard 3 1 calibration certificate per EN 10204 Option DKD DAkkS calibration certificate Recommended recalibration interval 1 year dependent on conditions of use Patents property rights Patents Design Registered under USD 786 719S Approvals and certificates see website ...

Page 8: ...WIKA data sheet CT 15 51 03 2019 Page 8 of 15 Dimensions in mm in Reference pressure sensor model CPT7000 Digital process calibrator model CPH7000 ...

Page 9: ...aximum and Minimum memory e g for leak testing Alarm function for safety testing For further information see the operating instruction Application icons app The home screen is very clearly subdivided into application oriented apps Measure Display of 3 different measurements Logger Simultaneous recording of up to 3 signals Info All instrument information available at a glance Remote WIKA Wireless r...

Page 10: ...ftware Up to 100 calibrations can be stored Re calibrations possible PC software available Communication with WIKA Cal calibration software via WIKA Wireless Operating mode Calibrate Features Pressure display on the closing and opening of the switch Automatic calculation of the hysteresis Operating mode Switch test Switch test with external voltage supply Switch test with voltage supply DC 24 V of...

Page 11: ...red value at the same time Automatic or manual data acquisition Direct display as graph or table Logger protocols are automatically saved Applications Logging of current voltage pressure and temperature The logger menu guides one step by step through the logger process The data sets incl date and time are automatically saved in the CPH7000 Before logging the data routines can be set directly on th...

Page 12: ...nder test DUT Kalibriergegenstand KG Environmental conditions Umgebungsbedingungen Place of calibration Ort der Kalibrierung Measurement conditions Messbedingungen Calibration certificate Kalibrierschein Customer Demo customer Kunde Demo street DE 12345 Demo city Customer order No Kundenbestellnummer Order date Bestelldatum Date of calibration 01 02 2017 Datum der Kalibrierung Operator Demo User B...

Page 13: ...e 7 Pressure connection set model Minimess 1620 incl test item hose length 1 m 3 28 ft 8 Dirt trap set Standard Consisting of Dirt trap Sealing set Hose Hose connection G via hose to G G NPT or NPT female L Dirt trap set with knurled nut Consisting of Dirt trap Knurled nut Sealing set Hose Hose connection G via hose to G G NPT or NPT female M Sealing set Consisting of 4 x G USIT seals 2 x G USIT s...

Page 14: ...ers T Sensor connection cable for reference pressure sensor model CPT7000 length 1 m 3 28 ft S for reference pressure sensor model CPT7000 length 3 m 9 84 V Temperature probe Pt100 uncalibrated P Atmospheric module E Power supply unit N WIKA Wireless USB Stick B Ordering information for your request 1 Order code CPH A 70 2 Option ...

Page 15: ...n certificate per DIN EN 10204 Options DKD DAkkS calibration certificate Service case with process calibrator and accessories completely equipped Process calibrator model CPH7000 Ordering information CPH7000 Version Pressure generation Unit Pressure type Measuring range Accuracy Type of certificate Barometer Barometer calibration Atmospheric module Atmospheric module calibration Temperature probe ...