background image

 

7- i Series Controls 

Our “i Series” Controls feature soft touch On/Off, Speed Up & Speed Down Buttons and a remote 
operation interface. It also features a visual and audible alarm system for the filters and the 
blower motors should service be required. The i-Series controls are equipped with an “Autoflow” 
pressure compensation feature. After setting the minimum speed required to properly evacuate 
your equipment the controls will automatically increase the motor speed to compensate for the 
increased pressure of dirtying filters until maximum speed is reached. As well after a filter change 
the system will automatically decrease the speed to the original set point.  

Remote Operation 

To enable the remote system startup simply ensure that the i-VAC system has the correct voltage 
connected to the unit, then connect the 9-pin control cable supplied with the system. Now when 
the unit receives a 24 VDC signal from the Zenotec unit the filter system will start automatically. 
The 

IVac System

 will respond by illuminating LED 1 (System On) & LED 5 (Remote/Standby). 

Whenever the remote signal is supplied the unit will instantly start, when the remote signal is 
stopped the unit will stop after a 3 second delay.  

 
If applicable set the shut off delay in Zenotec control software to the shortest possible 
interval. The iVac System has a 3 second delay that cannot be turned off.

 

 

Note: 

When operating by remote control the use of the On/Off (Power) button on the panel is 

disabled while the Remote/Standby light is ON Solid Or Fading In And Out. 
 
If you wish to use the On/Off button on the panel after Remote Operation has been enabled the 
function is only available when the Remote/Standby light is flashing slowly (No Remote signal is 
present, system is in standby). While in operation via the ON/Off (Power) button, remote 
operation is temporarily disabled. Turn the unit off with the ON/Off (Power) button to go back into 
Remote Operation. 

 

AUTOMATIC FILTER CLEANING 

The system is set from the factory to automatically clean the filter after every hour of operation.  

MANUAL FILTER CLEANING 

If additional cleaning is required, a MANUAL EXTRA CLEANING FEATURE is included.  To 
initiate, do the following: 
a)  Unit must be in operation (“SYSTEM ON” Led illuminated) 
b)  PRESS & HOLD POWER button for approximately 10 seconds (release button ONLY when 

you hear the BEEP) 

c)  Unit will STOP OPERATING 
d)  “Remote / Standby “ Led will illuminate,   Press POWER 
e)  EXTRA Cleaning will cycle ON (and clean out dust particles) for 10 seconds, Once cleaning is 

completed, unit will then go back to previous position. 

Summary of Contents for Zenotec Air+

Page 1: ...ZENOTEC Air Instructions for Use iVT16 912 120 volt iVT25 912 230 volt...

Page 2: ...three pronged plug on the end of the cord Disconnect power prior to accessing unit when checking or replacing filters or servicing motor blower When servicing the motors be careful when touching the...

Page 3: ...AYS CHECK SYSTEM VOLTAGE BEFORE PLUGGING INTO POWER SOURCE Warning This is a class A product In domestic environment this product may cause radio interference in which case the user may be required to...

Page 4: ...p after a 3 second delay If applicable set the shut off delay in Zenotec control software to the shortest possible interval The iVac System has a 3 second delay that cannot be turned off Note When ope...

Page 5: ...y 5 Mins 10 hrs of life left in brushes Unit Will SHUT DOWN In 10 Hours to prevent motor damage Flashing Quickly Illuminated FULLY Beep Every Second Motor Brush Life Expired Unit Shut Down Replace ALL...

Page 6: ...IN OUT FULLY Vacuum Controlled By Remote or mc2 Vaccum Cleans The ReStarts Vaccum...

Page 7: ...r spare parts and replace immediately 10 Filter Replacement Guide Filter requires replacement if appropriate light on control panel illuminates and beeper sounds for 2 seconds every 4 hours Filter rep...

Page 8: ...wer section door TURBINE BRUSHES are visible once door is removed RESETTING MICROPROCESSOR CONTROLLER AFTER REPLACING MOTOR BRUSHES If Motor Brushes are replaced WHILE BRUSH REPLACEMENT LIGHT was FLAS...

Page 9: ...hantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage No person firm or corporation is authorised to assume for QUATRO any other lia...

Page 10: ...s This ensures that patients can trust in the quality of their dentures and our partners in dental practices and laboratories can continue with confidence on the path to digitalisation and greater com...