Expansion port RS485/RS422 

 

 

Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C) 

26 

 

7.3

 

Expansion port connection RS485 

Panel socket RJ45. 

Pin 

Signal 

Description 

Direction 

GND 

Signal and supply ground 

 

GND 

Signal and supply ground 

 

TxRx- 

RS485 B (-) 

Input/Output 

TxRx+ 

RS485 A (+) 

Input/Output 

TxRx- 

RS485 B (-) 

Input/Output 

RXD- 

RS485 A (+) 

Input/Output 

+12 V EXT  External power supply 

 

+12 V EXT  External power supply 

 

 

 

Figure 19: RS485 port connector 

 

Power supply is selected on the expansion port RS485 by means of a jumper. 

 

The signals 3 – 5 and 4 – 6 are linked inside of the router.  

If galvanic separation is required, the converter must have an external power supply. 

Circuit example of the equipment with a router with data cable length less than 10 m 

 

Figure 20: Circuit equipment with a router with data cable length less than 10 m 

Circuit example of the equipment with a router with data cable length more than 10 m 

 

Figure 21: Circuit equipment with a router with data cable length more than 10 m 

With an RS485 data cable longer than 10 m it is necessary to use overvoltage protection on the 
router side!  

NOTICE 

NOTICE 

Summary of Contents for 83.041.0050.1

Page 1: ...User manual Doc no BA000917 Last updated 08 2021 Rev C wienet Router v2 Expansionports...

Page 2: ...its of the statutory provision of the Copyright Act Any modification or abridgment of the docu ment is prohibited without the express written agreement of Wieland Electric wienet is a trademark of Wie...

Page 3: ...fety 9 CNT expansion port 10 3 1 Description 10 3 2 Input and output description 10 3 2 1 Analog input 10 3 2 2 Binary input 10 3 2 3 Counter input 10 3 2 4 Binary output 11 3 3 Selecting the current...

Page 4: ...422 25 7 1 Description 25 7 2 Interface and power supply selection 25 7 3 Expansion port connection RS485 26 7 4 Expansion port connection RS422 27 7 5 Port status 28 7 6 Technical specifications 28 7...

Page 5: ...Table of contents Wieland Electric GmbH BA000917 08 2021 Rev C 5 Installing a router in a metal housing 39 Maintenance 41 Product disposal 42 Service and Support 43...

Page 6: ...installation manual The installation instructions accompanying the product is downloadable in the electronic catalog of Wieland Be sure to always use the information provided in the current version o...

Page 7: ...h points etc It is used exclusively in danger of personal injury The symbol WARNING indicates a possible threat If it is not avoided can result in death or serious injury could result The symbol CAUTI...

Page 8: ...ements con tained in this manual The applicable local safety protection and installation requirements must be observed The user is solely responsible for selecting the correct product and the technica...

Page 9: ...a plane may endanger the operation of the plane or interfere with the mobile telephone network and may be unlaw ful Failure to observe these instructions may result in the suspension or cancellation...

Page 10: ...0 The sample period on analogy inputs is adjustable in range 0 65535 seconds At value 0 it is sam pling once per second and measurement circuit is permanent switch on At sampling it is possible to set...

Page 11: ...oltage of the router The impulse length is possible to set in a range of 125 8000 ms which is possible to send on output after impulses number setting 1 65535 on input BIN1 CNT1 In sleep mode the all...

Page 12: ...2 Binary input counter input Input 3 BIN3 Binary input Input 4 BIN4 Binary input Input 5 GND Signal ground 6 OUT1 Binary output open collector Output 7 AN1 Analogue input Input 8 AN2 Analogue input In...

Page 13: ...counter CNT1 CNT2 0x0004 R Maximal logs number in buffer 0x0005 R W Marker of log launching and alarms work 0x0006 R W Upper 16 bits of seconds number from 1 1 1970 0x0007 R W Lower 16 bits of seconds...

Page 14: ...R Maximal frequency CNT1 0x0F0E R Upper 16 bits of counter CNT2 value 0x0F0F R Lower 16 bits of counter CNT2 value 0x0F10 R Prompt frequency CNT2 0x0F11 R Average frequency CNT2 0x0F12 R Minimal frequ...

Page 15: ...bit 3 input BIN4 0xF200 W Binary outputs normal level Bit 0 output OUT1 0xF201 W Feeder impulse number on input BIN1 CNT1 0xF202 W Feeder impulse length on output OUT1 1 8 sec 0xF300 W AN1 samples per...

Page 16: ...for metering reset sec 0xFFFF W Switch main supply off on set time min 3 6 Port status LED port indicator Green LED Indicates binary input 0 Yellow LED Indicates binary input 1 Status indication is su...

Page 17: ...ieland Electric GmbH BA000917 08 2021 Rev C 17 Sleeping mode Controlled 3 8 Delivery identification Trade name Type name Power supply XC CNT XC CNT Internal or external supply Figure 4 Example of expa...

Page 18: ...supplies from appropriate modem Against bus overload the expansion port ETH is protect Expansion port ETH is only possible at PORT1 4 2 Expansion port connection Panel socket RJ45 Pin Signal Descript...

Page 19: ...supported from 2nd revision of boards 4 4 Technical specifications Expansion port ETH Power supply Internal 3 3 V Environment Operating temperature 30 60 C Storage temperature 30 85 C Standards Emissi...

Page 20: ...US is only possible at PORT1 and PORT2 5 2 Expansion port connection Panel socket RJ45 Pin Signal Description Direction 1 GND Signal and supply ground 2 GND Signal and supply ground 3 TxRx M BUS B Inp...

Page 21: ...o the bus They can trigger overcurrent detection by their own power consumption Overcurrent protection can be triggered also by connecting a critical number of meters when power consumption can rise a...

Page 22: ...sion port MBUSD Wieland Electric GmbH BA000917 08 2021 Rev C 22 5 6 Delivery identification Trade name Type name Power supply XC MBUS XC MBUS External supply Figure 11 Example of expansion port MBUSD...

Page 23: ...tect Expansion port RS232 is only possible at PORT1 and PORT2 6 2 Expansion port connection Panel socket RJ45 RS232 DCE Data Communication Equipment Pin Signal Description Direction 1 RTS Request To S...

Page 24: ...chnical specifications Expansion port RS232 Power supply Internal 3 3 V Environment Operating temperature 30 60 C Storage temperature 30 85 C Standards Emission EN 55022 B Immunity ETS 300 342 Safety...

Page 25: ...pers J2 and J3 on this module If an internal power supply of the module is required jumpers J2 and J3 must be connected to pins 2 3 External power supply is made by connecting pins 1 2 with jumpers J2...

Page 26: ...selected on the expansion port RS485 by means of a jumper The signals 3 5 and 4 6 are linked inside of the router If galvanic separation is required the converter must have an external power supply Ci...

Page 27: ...onnector Power supply is selected on the expansion port RS422 by means of a jumper If galvanic separation is required the converter must have an external power supply Circuit example of the equipment...

Page 28: ...Internal 3 3 V Supply power Max 1 W Supply current Max 4 mA Environment Operating temperature 30 60 C Storage temperature 30 85 C Standards Emission EN 55022 B Immunity ETS 300 342 Safety EN 60950 RS4...

Page 29: ...omatic configuration of connected de vices DHCP server Expansion port Wi Fi supports these standards 802 11b 1 2 5 5 11 Mbps 802 11g 6 9 12 24 36 48 54 Mbps 802 11n 20MHz MCS0 7 up to 72 Mbps 40MHz MC...

Page 30: ..._erp Number of associated Non ERP stations i e stations using 802 11b in 802 11g BSS num_sta_no_short_slot_time Number of associated stations that do not support Short Slot Time num_sta_no_short_pream...

Page 31: ...ination IP address validity hardware ethernet Hardware MAC unique address uid Unique ID Figure 28 Wi Fi DHCP status 8 2 1 3 Scan If you want to scan neighboring Wi Fi networks press Scan item Scanning...

Page 32: ...nt WiFi AP hostapd is an exception This component writes every report to the System Log Figure 30 Wi Fi AP Start Log 8 2 1 5 System Log In case of any problems with the Wi Fi connection it is possible...

Page 33: ...hen it may come a pass a breach of regulatory rules for the using of frequency bands in the particular country HW model HW mode of Wi Fi standard that will be supported by Wi Fi access point IEE 802 1...

Page 34: ...must be entered according to the selected WPA PSK type as follows 256 bit secret 64 hexadecimal digits ASCII passphrase 8 to 63 characters then these characters are con verted to PSK PSK File absolute...

Page 35: ...ss of Wi Fi network interface Subnet mask IP address of Subnet Mask Bridged No Bridged mode is not allowed WLAN network is not con nected with LAN router Yes Bridged mode is allowed WLAN network is co...

Page 36: ...20 85 C Standards Emission EN 55022 B Immunity ETS 300 342 Safety EN 60950 Isolation EN 60747 WIFI specifications 802 11 b g n RX sensitivity 11b 11 Mbit s 11g 54 Mbit s HT20 11n MSC7 HT20 11n MSC7 85...

Page 37: ...SD card acts as a USB flash drive For this function the router must be equipped with a jumper for jumper position see figure below otherwise this function will be blocked Jumper is usually equipped in...

Page 38: ...n a file is copied to the SD card 9 6 Technical specifications Expansion port SD Power supply Internal 3 3 V Environment Operating temperature 30 60 C Storage temperature 40 85 C Standards Emission EN...

Page 39: ...RT2 4 Left sidewall 5 Right sidewall 6 Rear panel 7 Front panel 8 Bottom cover 9 Top cover 10 Spacers 6 11 Screws 8 Unscrew the four screws pos 11 on the rear panel pos 6 and remove it Take out the ro...

Page 40: ...C 40 Slide the router motherboard with expansion ports into the housing Close the rear panel pos 6 by screwing the four screws pos 11 back in Attach the label that is included in the delivery to the s...

Page 41: ...11 MAINTENANCE The SIM card must be handled as carefully as a credit card Do not bend or scratch the SIM card Do not expose the SIM card to static electricity During cleaning of the router do not use...

Page 42: ...very techniques in order to minimize impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed w...

Page 43: ...fo wieland electric com http eshop wieland electric com http www wieland electric com Admission Wieland Electric hereby declares that the router described in this user manual fits all basic demands of...

Page 44: ...Wieland Electric GmbH Brennerstra e 10 14 DE 96052 Bamberg Tel 49 951 9324 0 Fax 49 951 9324 198 info wieland electric com www wieland electric com...

Reviews: