Wiedamark Galaxias 12 User Manual Download Page 3

02

Specifications on Galaxias Series

All dimensions are in millimeter

Model  No

Pixel pitch

Density

Pixel Configuration

Brightness

View distance

 Max.Power 
Consumption

Consumption

Module size
W=width
H=height
T=thickness

Weight

Work Voltage

Brightness level

Bit depth per color

Bit depth per pixel

Visual Angle

Date Refresh Rate

Display mode

Drive mode

Signal type

Contol Distance

Body structure

IP

   Ambient 

Temperature

Relative humidity

Power system

Installation

safety certificate

DC 24V

16 levels

16 bit

48 bit

Horizontal:120˚  Vertical:120˚

10000Hz

1280X1024

Constant current

AV,S-Video,VGA,CVBS,HDMI,DVI 

HSYV; <100m

Plastic 

 Ip43 

-20 ~ +50 °C

10% ~ 90%

Power-600, Power-1200 Power jacket

Hang

CE  FCC  ROHS

Average.power

Galaxias 6

RGB 3-IN-1  SMD

Galaxias 7

Galaxias 9

Galaxias 12

Galaxias 16

6.25mm

7.8125mm

9.375mm

12.5mm

16mm

27778 Dot/m²

16384 Dot/m²

11378 Dot/m²

6400 Dot/m²

3906 Dot/m²

2600 nit

2730 nit

2100 nit

1650 nit

1300 nit

4.5m

5m

7m

9m

12m

205W/m²

195W/m²

185W/m²

180W/m²

230W/m²

67W/m²

69W/m²

65W/m²

63W/m²

80W/m²

W:800mm
H:2400mm
T:25mm

W:1000mm

W:600mm

W:800mm

W:512mm

H:2400mm

H:2400mm

H:3200mm

H:3072mm

T:25mm

T:25mm

T:25mm

T:25mm

11.5Kg/sq.m

11.0Kg/sq.m

10.4Kg/sq.m

9.8Kg/sq.m

9.2Kg/sq.m

Summary of Contents for Galaxias 12

Page 1: ...User Manual Galaxias Flex LED display...

Page 2: ...Specifications 2 Dimension 3 Attentions 4 Introduction 5 Transportation 6 Installation 7 Maintenance 10 Troubleshooting 11 Conterts 01...

Page 3: ...levels 16 bit 48 bit Horizontal 120 Vertical 120 10000Hz 1280X1024 Constant current AV S Video VGA CVBS HDMI DVI HSYV 100m Plastic Ip43 20 50 C 10 90 Power 600 Power 1200 Power jacket Hang CE FCC ROH...

Page 4: ...omized to achieve your needs Manufacturer disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or...

Page 5: ...appointed connectors by our company Cables are not allowed to get wet in rain One power socket can supply maximum 2 powers 2400W Please check rated power and all accessories to make sure safety befor...

Page 6: ...enance much easier 4 Lightweight makes transportation and installation cost saved 5 We use led light as illuminant about 100 000 hour lifetime Besides it is also with lower power consumption and energ...

Page 7: ...duel can be fold to unidirectional it will be more convenient for transportation and storage Warning The folding pattern must be following the sketch pictures otherwise all the damage will be assumed...

Page 8: ...er if there is any question Warning The default installation of the screen is girder hanging please consult the professionals if using other installations 1 Hanging Screen A B C D E Steps 1 Unfold the...

Page 9: ...A into the combination buckle B and flattening the screen tightening the buckle and screw B 3 Horizontal combination Steps 1 Loose the combination buckle of the left screen Display A and lock the scre...

Page 10: ...09 AC Input All the electrical connection of Galaxias are completed by connector Diagram7...

Page 11: ...connected with net cable There are two groups of net cables one is for output signal another is for input signal the input net cable and video processor s cable are connected by contactor output net...

Page 12: ...upply is switched on Warning The earth connection must be examined to be qualified before the power supply is switched on Warning The power supply can t be poured by rain or any water on it Maintenanc...

Page 13: ...ly Panel is too hot Fault on line connection Device on line connection All panels and or monitor screen display video incorrectly or do not display video at all Incorrect video input or panel settings...