Kunststoffschweißtechnik
Foundation: 2207, 2208 DIN 16932 German association for welding
Use for:
HRG 8 / 10 / 12 / 14 / 16
1 bar on manometer:
463
N
PE 80
The value for heating element temperature is between 200° C - 220° C.
The
smaller
the pipe wall the
higher
the temperature.
PE 100
The standard value for heating element temperature is 220° C.
Increase the change-over time and the welding pressure time at PE 100 as fast as possible !
time to
change-
reach full
over
welding
cool-down time
0,15 (PE)
time
pressure
pressure in
T
desired
temperature
time
pipe
pipe
SDR
bead-up
circular
heat-up
max.
time
welding
cool-
diameter wall
pressure bead
time
change-
to reach
pressure down
OD
(s)
[bar]
min.
[s]
over
welding
[bar]
time
[mm]
[mm]
[mm]
time
pressure
[min]
[s]
[s]
in welding area
Table for PE
bead-up
heat-up
Additional to the given bead-up force and to the welding force the moving force of the support must be added !
welding area
P (N/mm²)
1200
29,4
41
36
3,0
294
13
16
36
36
1200
36,7
33
44
3,0
367
16
19
44
45
1200
45,9
26
54
3,5
459
19
23
54
55
1200
57,2
21
67
4,0
572
22
29
67
67
1200
68,0
17,6
79
4,0
680
24
34
79
78
1400
34,4
41
48
3,0
344
15
18
48
42
1400
42,9
33
60
3,5
429
18
22
60
52
1400
53,5
26
74
4,0
535
21
27
74
64
1400
66,7
21
91
4,0
392
24
33
91
77
1600
39,2
41
63
3,5
667
17
20
63
48
1600
49,0
33
78
3,5
490
20
25
78
59
1600
61,2
26
96
4,0
612
23
31
96
71
Remaining under the cool-down time for up to 50% is allowed under the following conditions:
•
prefabrication under workshop conditions
•
low additional pressure at unclamping
•
no additional pressure during further cooling down
•
load onto the workpieces only after being completely cooled down
26.04.2011
Working instructions WIDOS HRG 10
Page 26 / 3 of 49