SABRE
TM
Shield Installation Guide
14
4. Install the Multi-function cable header to the connector on the SABRE
TM
Shield.
Follow these steps to position the SABRE
TM
Shield:
1. Remove two lock bolts and nuts on either side of the mounting frame.
2. Adjust the elevation of the SABRE
TM
Shield and secure its position using the
two lock bolts and nuts on either side of the mounting frame.
3. Secure the length of the Multi-function cable to the pole or column using
cable ties.
Note:
Ensure there is some slack at both ends of the Multi-function cable to avoid any
stress build-up, which may damage the cable.
Lock bolt for
elevation
12 Positioning the SABRE
TM
Shield
Multi-function
cable header